9
ENGLISH
Patented Monster T2
™
Technology
The Monster HDP 1250G+
features exclusive Monster T2
™
technology. T2 is an active electronic
microprocessor-controlled circuit
that sits in front of the surge protection circuitry in select Monster
Power products. T2 monitors the line, neutral and ground lines
and automatically disconnects the PowerCenter from the AC
power line when a long duration low-voltage sag or high-voltage
swell occurs (continuous voltage below 80Vrms or above 132Vrms).
When the voltage sags or swells to these potentially damaging
levels, ultra-fast T2 auto-disconnect protection circuitry shuts down
the Monster PowerCenter for 15 seconds. When the under-voltage
or over-voltage condition returns to normal, T2 reconnects
the PowerCenter to the electricity and resets to full operation
after 15 seconds. If the power fault condition does not clear,
the T2 comparator circuit keeps the unit shut down.
Unlike ordinary power management devices, T2 will shut down
your PowerCenter before the MOVs (Metal Oxide Varistors)
and thermal fuses sense an overload condition and sacrifice
themselves to protect your connected components. This will
extend the PowerCenter’s life, while providing the system
protection you need.
Advanced Tri-Mode
®
Surge Protection
For added protection against
more powerful overloads, patented
Monster Tri-Mode automatically
disconnects your equipment
and sounds an alarm. Tri-Mode protects against surges and spikes
on all three power lines (line, neutral, and ground) for a triple layer
of safety. Only Tri-Mode offers this level of protection.
LIT_MANUL_HD_NA_G1jl.indd 9
1/18/12 4:22 PM
Summary of Contents for HDP 1250G+
Page 2: ...LIT_MANUL_HDP_1250G _NA_G1jl indd 2 1 18 12 4 22 PM ...
Page 4: ...LIT_MANUL_HDP_1250G _NA_G1jl indd 2 1 18 12 4 22 PM ...
Page 6: ...4 LIT_MANUL_HDP_1250G _NA_G1jl indd 4 1 18 12 4 22 PM ...
Page 26: ...24 LIT_MANUL_HDP_1250G _NA_G1jl indd 24 1 18 12 4 22 PM ...
Page 28: ...26 LIT_MANUL_HDP_1250G _NA_G1jl indd 26 1 18 12 4 22 PM ...
Page 50: ...48 LIT_MANUL_HDP_1250G _NA_G1jl indd 48 1 18 12 4 22 PM ...
Page 52: ...50 LIT_MANUL_HDP_1250G _NA_G1jl indd 50 1 18 12 4 22 PM ...
Page 74: ...LIT_MANUL_HDP_1250G _NA_G1jl indd 72 1 18 12 4 22 PM ...
Page 75: ...LIT_MANUL_HDP_1250G _NA_G1jl indd 73 1 18 12 4 22 PM ...