CHECKING FOR LEAKS
BEFORE USE CHECK FOR LEAKS
Never check for leaks with a naked flame, always use a soapy water solution
•
Make 50
–
75ml of leak detecting solution by mixing ¼ washing up liquid with 3/4 water.
•
Ensure the control dials on the BBQ are set to the OFF position
.
•
Connect the regulator to the cylinder, ensuring that all the connections are secure before turning
ON the gas.
•
Brush the soapy solution onto the hose and all joints. If bubbles appear you have a leak, which
must be rectified before use.
•
Turn OFF the gas at the cylinder after testing.
•
If a leak was detected, retest the BBQ for leaks after taking the appropriate action to resolve the
leak.
•
If leakage is detected and cannot be rectified, do not attempt to repair the leakage but consult a
suitably qualified technician.
LIGHTING INSTRUCTIONS
If any burner fails to ignite after a number of attempts, turn the control dial to the off position
(clockwise) and also turn the cylinder valve off. Wait for five minutes before attempting to light the
BBQ again.
LIGHTING INSTRUCTIONS FOR THE MAIN BURNER
1.
Open the lid and make sure that all burners are in the OFF position
2.
Connect the regulator to the gas bottle. Turn the gas supply to “ON” position on the
regulator. Use soapy water to check if there is any gas leakage between the Bottle and the
regulator.
3.
Push down control knob and turn it anti-clockwise to the position, this will light the
burner.
4.
If the burner fails to ignite, turn the control knob off (clockwise) and also turn the cylinder
valve off. Wait 5 minutes and repeat step 3.
5.
Adjust the heat by turning the knob to the High/Low position.
6.
To turn OFF the barbecue, turn the control knob on the appliance clockwise to the “OFF”
position and then turn the cylinder valve or regulator switch to the “OFF” position.
Warning:
If any burner fails to ignite, turn the control knob off (clockwise) and also turn the
cylinder valve off. Wait five minutes before attempting to relight.