background image

Mono2 - Build Platform 

Calibration (Leveling)

Ver. 1.1

Dec. 26, 2017

1

Summary of Contents for Mono2

Page 1: ...Mono2 Build Platform Calibration Leveling Ver 1 1 Dec 26 2017 1...

Page 2: ...finish the printer setting Press Connect button Then MonoWare will connect to Mono1 If the connection is successful the firmware version will be displayed and the motor position will be updated Latest...

Page 3: ...3 Build platform calibration 1 Build platform calibration will use above MonoWare buttons After Mono2 is connected to PC move the platform upward by 50 mm or higher...

Page 4: ...erent kinds of screws on the build platform 4 x m4 thumb screws yellow circles above 2 x m4 hex screws blue circles and m5 hand screw at the center red You need to operate these screws one by one thum...

Page 5: ...tion 3 Loosen thumb screws Loosen hex screws Slightly engage the hand screw Caution If you fully unscrew hex screws the platform may fall down to the vat Check if the platform is still engaged while l...

Page 6: ...d or forcing it down further After homing process the build platform should be freely movable there should be a small gap between Gently tighten the thumb screws x4 Check if the hex screws are still l...

Page 7: ...which makes scratches on the film Then gently tighten the hex screws Do push hard Mild force will be okay to fix the position Finally tighten the central hand screw After all screws are tighten the bu...

Page 8: ...platform upward by 70 mm Pour resin with 2 3 mm deep for Mono2 resin tank or 5 7 mm deep for Mono1 tank With a well calibrated build platform you can see the aluminum build plate through the bottom g...

Page 9: ...led prints Q How often do I need to repeat this process A When you use the same build platform and vat you can keep the current calibration for a day or two but re calibration can be done quickly Q Ca...

Page 10: ...Thank you Send an email at info monoprinter com for any questions 10...