INCLUSION 

Now that the plugin is in its final location, it can be "included" into the network. Bring 
your Z-Wave Interface Controller to the Plugin's location. The distance between the 
controller and the plugin should be less than 1 meter during the "inclusion" process. 

1. Following the instructions that came with your Z-Wave Controller, set it to

"include" mode. 

2. When prompted, press and hold the Program Switch on the plugin for about 1

second. 

EXCLUSION 

If you wish to remove the plugin from your network, you will need to "exclude" it. 

1. Following the instructions that came with your Z-Wave Controller, put the

controller in "exclude" mode. 

2. When prompted, press and hold the Program Switch on the plugin for about 1

second to complete the "exclusion". 

PROTECTION FUNCTION 

The Protection function allows you to control whether the Program Switch is functional 
or not. 

Protection State=0x00:

 Normal unprotected state, the Program Switch operates as 

described in the Operation section. 

Protection State=0x01:

 Restricted state, the Program Switch must be pressed 

three times instead of only one to manually switch the appliance on or off. 

Protection State=0x02:

 Fully protected state, the Program Switch is inoperative. 

Z-WAVE COMMAND CLASSES 

This plugin supports the following Z-Wave Command Classes: 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 

COMMAND_CLASS_PROTECTION 

COMMAND_CLASS_SWITCH_ALL 

COMMAND_CLASS_SWITCH_BINARY 

COMMAND_CLASS_VERSION 

Summary of Contents for z-wave

Page 1: ......

Page 2: ...receiving the product please inventory the contents to ensure you have all the proper parts as listed below If anything is missing or damaged please contact Monoprice Customer Service for a replacement 1x Z Wave On Off Plugin 1x User s Manual ...

Page 3: ... you are installing a complete Z Wave system for the first time please refer to the installation guide of your Z Wave Interface Controller before installing this Shock Sensor 1 Plug the plugin into an AC power outlet If plugged into the top outlet of a standard two plug wall outlet it will not block the lower outlet 2 Plug the appliance device you will be controlling into the Z Wave outlet on the ...

Page 4: ...troller in exclude mode 2 When prompted press and hold the Program Switch on the plugin for about 1 second to complete the exclusion PROTECTION FUNCTION The Protection function allows you to control whether the Program Switch is functional or not Protection State 0x00 Normal unprotected state the Program Switch operates as described in the Operation section Protection State 0x01 Restricted state t...

Page 5: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and ...

Reviews: