Monogram ZHU36RDTBB Quick Start Manual Download Page 3

For questions about your  

appliance, please call 1-800-626-2000.

PAGE 3 OF 5

Product Specification Created 9/22

HELPFUL TIPS

INSTALLATION

3"

(7.6) min

19 1/8" 

(48.6) min

19 1/4" 

(48.9) max

Cutout depth

5"

(12.7) min

16" 

(40.6) min

To electrical junction box

Locate electrical junction box

at least 

16" 

below the countertop

15"

(38.1)

min

13"

(33.0) max

33 7/8" 

(86.0) min

34" 

(86.3) max

Cutout width

36 " 

(91.4)

Cabinet base

SIDE VIEW

FRONT VIEW

TOP VIEW OF CUTOUT

SIDE VIEW

DRAWER

FRONT

ZHU36RSJSS

1 3/4" 

(4.5) min

Clearance between the

rear edge of the cutout

and the nearest wall

behind the cooktop

2 1/2" 

(6.4) min

Clearance between the

front edge of the cutout

and the front edge of the

countertop

3"

(7.6) min

19 1/8" 

(48.6) min

19 1/4" 

(48.9) max

Cutout depth

5"

(12.7) min

16" 

(40.6) min

To electrical junction box

Locate electrical junction box

at least 

16" 

below the countertop

15"

(38.1)

min

13"

(33.0) max

33 7/8" 

(86.0) min

34" 

(86.3) max

Cutout width

36 " 

(91.4)

Cabinet base

SIDE VIEW

FRONT VIEW

TOP VIEW OF CUTOUT

SIDE VIEW

DRAWER

FRONT

ZHU36RSJSS

1 3/4" 

(4.5) min

Clearance between the

rear edge of the cutout

and the nearest wall

behind the cooktop

2 1/2" 

(6.4) min

Clearance between the

front edge of the cutout

and the front edge of the

countertop

A

   Wall coverings, countertop and cabinets 

surrounding cooktop must be able to 

withstand temperatures of up to 200ºF.

B

   Minimum 30" clearance from countertop 

to unprotected overhead surfaces, when 

no ventilation hood or microwave oven 

is installed.

C

   When using a ventilation hood or 

microwave oven above the cooktop, 

see hood or microwave installation 

instructions for minimum overhead 

clearance dimensions.

D

   Minimum 15" of clearance from 

countertop to nearest overhead surface 

on both sides of cooktop. Make sure 

to include any lighting rail covers in 

calculation.

E

   Minimum 2" distance from edge of 

cutout to nearest adjacent side wall below 

upper cabinets.

F

   Install an approved junction box where it 

can be easily reached through the front of 

the cabinet where the cooktop is located. 

IMPORTANT: For serviceability, the 

junction box must be located where it 

will allow considerable slack in the 48" 

long conduit.

G

   Maximum 13" depth of unprotected 

overhead surfaces, when no ventilation 

hood or microwave oven is installed.

H

   For Americans with Disabilities Act 

(ADA) forward approach installation: 

Minimum 5" clearance between the top 

of the countertop and the enclosure. The 

enclosure must be made of at least 1/4" 

thick wood material, and must have an 

access panel installed in order to provide 

access to the junction box and hold-

down brackets, and to allow for service 

of the cooktop.    

I

   Allow 3” minimum vertical clearance 

for air space from the cooktop bottom 

(or 5-7/8” minimum depth from the 

countertop) to any combustible surfaces, 

such  as  the  top  of  a  cabinet  drawer.                                                                                                            

For more details refer to the installation 

instructions for this product.

COUNTERTOP CUT-OUT  

DIMENSIONS

ADA INSTALLATION

Dimensions in parentheses are in centimeters unless otherwise noted.

B

A

C

D

H

E

G

F

I

Reviews: