7

Cabinetry

NOTE: Additional clearances between cutouts
may be required. Check to be sure the oven
supports above the Warming Drawer location
do not obstruct the required interior depth and
height.

• When installing a Monogram Warming

Drawer below a single or double oven, a
separate 120V, 60 Hz, properly grounded
receptacle must be installed. Refer to
installation instructions packed with the
Warming Drawer for specific installation
requirements.

Frameless Cabinets

Whenever possible, order 30

” 

(76.2 cm)

frameless cabinet with the cutout sided to fit
the oven. If using stock cabinets, additional
finished filler pieces may be required to
cover the opening.
• A stock frameless cabinet cutout width

may be up to 28 3/4

” 

(73 cm). If necessary,

add 1/2

 (1.3 cm) cleats to the sides, flush

with the front edge of the side panels to
accept mounting screws.

NOTE: Install the
oven only with
specific models
listed on the label
located on top of
the oven.

Cutout for Frameless Cabinets

A6

Single Oven Cutout
for Installation Over
a Monogram Warming
Drawer

A4

Double Oven Cutout
for Installation Over
a Monogram Warming
Drawer

A5

Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement

2

 (5.1 cm) Min.

1

 (2.5 cm) Min. Above Toekick or

Adjust to Oven Installation Height

Anti-Tip Block
Against Rear
Wall Per
Warming
Drawer
Requirement

2

 (5.1 cm)

Min.

1

 (2.5 cm) Min. Above Toekick

Cabinet Depth
23 1/2

 (59.7 cm)

Min. From Inside
Back to Front of
Cabinet Frame
or Side Panel

3/4

 (1.9 cm) Min.

Thick Bottom Shelf
Cut Back Flush
with Front of
Side Panel

Install 1/2

(1.3 cm)
Cleats to
Hold Oven
Mounting
Screws

30

(76.2 cm)

28 1/2

 (72.4 cm)

Min.

28 5/8

 (72.7 cm)

Max.

Double
51 15/16

 (131.8 cm)

Single
27 5/16

 (69.2 cm)

Per Warming
Drawer
Requirement

Per Warming
Drawer
Requirement

Summary of Contents for ZET2PMSS

Page 1: ...ents of the National Electrical Code ANSI NFPA No 70 Latest Edition You can get a copy by writing National Fire Protection Association Batterymarch Park Quincy MA 02269 Effective January 1 1996 the Na...

Page 2: ...ottom trim may not install correctly and then interfere with the door opening Side by Side Installations Install two wall ovens in separate cutouts Allow 2 5 1 cm min between cutouts 2 5 1 cm Min Cuto...

Page 3: ...AT LEAST 28 1 2 WIDE ALLOW 1 FOR OVERLAP ON OVEN TOP AND BOTTOM OF CUTOUT 21 ALLOW A MINIMUM OF 21 FOR CLEARANCE TO ADJACENT CORNERS DRAWERS WALLS ETC WHEN THE DOOR IS OPENED 30 CABINET WIDTH RECOMME...

Page 4: ...installed over this oven See cooktop installation instructions for cutout size See label on top of oven for approved cooktop models 28 1 2 72 4 cm Min 28 5 8 72 6 cm Max NOTE This oven is only approve...

Page 5: ...ush with the front edge of the side panels to accept mounting screws NOTE Install the oven only with specific models listed on the label located on top of the oven Cutout for Frameless Cabinets A6 Sin...

Page 6: ...wer do not obstruct the required interior depth and height The middle rail separating the openings may need to be larger than the 2 5 1 cm minimum shown Always refer to the individual installation ins...

Page 7: ...he conductor is governed by the wire gauge and the temperature rating of the insulation around the wire Turn off the circuit breaker or remove fuses to the oven branch circuit With the oven supported...

Reviews: