7
Cabinetry
NOTE: Additional clearances between cutouts
may be required. Check to be sure the oven
supports above the Warming Drawer location
do not obstruct the required interior depth and
height.
• When installing a Monogram Warming
Drawer below a single or double oven, a
separate 120V, 60 Hz, properly grounded
receptacle must be installed. Refer to
installation instructions packed with the
Warming Drawer for specific installation
requirements.
Frameless Cabinets
Whenever possible, order 30
”
(76.2 cm)
frameless cabinet with the cutout sided to fit
the oven. If using stock cabinets, additional
finished filler pieces may be required to
cover the opening.
• A stock frameless cabinet cutout width
may be up to 28 3/4
”
(73 cm). If necessary,
add 1/2
”
(1.3 cm) cleats to the sides, flush
with the front edge of the side panels to
accept mounting screws.
NOTE: Install the
oven only with
specific models
listed on the label
located on top of
the oven.
Cutout for Frameless Cabinets
A6
Single Oven Cutout
for Installation Over
a Monogram Warming
Drawer
A4
Double Oven Cutout
for Installation Over
a Monogram Warming
Drawer
A5
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2
”
(5.1 cm) Min.
1
”
(2.5 cm) Min. Above Toekick or
Adjust to Oven Installation Height
Anti-Tip Block
Against Rear
Wall Per
Warming
Drawer
Requirement
2
”
(5.1 cm)
Min.
1
”
(2.5 cm) Min. Above Toekick
Cabinet Depth
23 1/2
”
(59.7 cm)
Min. From Inside
Back to Front of
Cabinet Frame
or Side Panel
3/4
”
(1.9 cm) Min.
Thick Bottom Shelf
Cut Back Flush
with Front of
Side Panel
Install 1/2
”
(1.3 cm)
Cleats to
Hold Oven
Mounting
Screws
30
”
(76.2 cm)
28 1/2
”
(72.4 cm)
Min.
28 5/8
”
(72.7 cm)
Max.
Double
51 15/16
”
(131.8 cm)
Single
27 5/16
”
(69.2 cm)
Per Warming
Drawer
Requirement
Per Warming
Drawer
Requirement