16
49-60532-10
PROBLEM
POSSIBLE CAUSE
INTERIOR LIGHT DOES
NOT WORK
• No power at outlet.
• Light bulb needs replacing. See Care and Cleaning.
• Controls are set to OFF. Press
LIGHT
pad on control panel.
• The Sabbath Mode may be operating. Turn off Sabbath Mode.
HOT AIR FROM BOTTOM
OF APPLIANCE
• Normal air flow cools the motor. In the refrigeration process, it is normal that heat be
expelled in the area under the appliance. Some floor coverings are sensitive and will
even discolor at these safe and normal temperatures.
APPLIANCE NEVER
SHUTS OFF BUT
TEMPERATURES ARE OK
• Adaptive defrost keeps compressor running during door openings. This is normal.
The appliance will cycle off after the door remains closed for two hours.
• Normal operation in extreme temperatures.
TEMPERATURE WILL NOT
ADJUST
• Temperature may be in lockout mode. Press both
+
and
–
pads for 5 seconds to
unlock the temperature.
• Thermistor may be blocked, which can affect the overall temperature. The thermistor
is located on the right-hand side, just above the third shelf.
TROUBLESHOOTING