– 18 –
4. Disconnect the wiring harness connector and
water line from the water valve.
GEA00667
Connector
Connector
Copper
Tubing
Copper
Tubing
Water
Valve
Water
Valve
Water
Line
Water
Line
5. Disconnect the copper tubing from the water
valve.
To Replace the Water Line from the Water Valve to
the Fill Tube Grommet:
Note: Some water may leak from the water supply
line and valve when they are disconnected.
1. Shut off the water supply to the freezer.
2. Remove the unit from its installation (see GE
Publication 49-60055, GE Monogram 36”
Refrigerators and 36” Freezers Custom
Options Guide and Installation
Instructions, pages 12-17).
3. Loosen 3 clamp screws.
4. Loosen the clamp at the fill tube grommet.
Caution: Do not lose the tubing sleeve when
removing the water line from the fill tube grommet.
The sleeve must be used during reassembly to
avoid leaking.
5. Remove the water line from the fill tube
grommet.
6. Remove the sleeve from the water line.
7. Slide the water line down and out of 3 clamps.
GEA00638
Clamp Screws
Clamp Screws
Fill Tube Grommet
Fill Tube Grommet
Water Line
Water Line