Data Communications:

The Wireless Communication Interface can receive data
communications through one of two wiring media: either
RS-485 half-duplex or RS-232.  Before wiring, determine
which data communication wiring medium is to be tied to
the Wireless Communication Interface and proceed as fol-
lows (Refer to Setup section for further explanation).

1) RS-232 Connection (if applicable):

(See Figure 8) A

single network 

Silo

Track

/PC system can be connected

directly to the Wireless Communication Interface using
the PC’s RS-232 serial port.  RS-232 is intended for 
use in office environments where interconnection dis-
tances are short (less than 12 feet) and where heavy 
electrical circuits (motors, contactors, etc.) are not 
present.  The interconnection must be done point-to-
point (no multi-dropping or networking) with a 3-
conductor cable (such as Belden 9533 or Alpha 6303).
Determine the type of connector on the PC, source a 
suitable mating connector (See Table 1) then intercon-
nect as described in Table 2.

CONNECTOR TYPE

AMPHENOL

NORCOMP

9-pin D-sub, male con

17-DE09P

172-009-101-001

9-pin D-sub, female con

17-DE09S

172-009-201-001

9-pin D-sub back shell

17-1724-1

972-009-010-011

25-pin D-sub, male con

17-DB25P

172-025-101-001

25-pin D-sub, female con

17-DB25S

172-025-201-001

25-pin D-sub back shell 

17-1726-1

972-025-010-011

Figure 8

Table 1

PC PORT

WIRELESS COMMUNICATION

INTERFACE

DB-25

DB-9

Terminal Block 

Transmit

2

3

Rx

Receive

3

2

Tx

Signal ground

7

5

GND

Chassis ground

1

N/A

Shield

Table 2

Summary of Contents for SiloPatrol

Page 1: ...e equipment and the safety of all personnel Before discarding shipping container or the internal packing materials please inspect the packaging thoroughly and verify that all parts are accounted for This product is shipped with the antenna and mounting plate with its fasteners detached from the Wireless Communication Interface radio module In the event that information contained herein does not co...

Page 2: ... to the Wireless Communication Interface radio module In some challenging applications it maybe necessary to install a higher performance antenna that requires co axial cabling between the radio and the antenna The co axial cable introduces loss into the system thereby negating some benefit of the better antenna In these applications keep the coaxial cable as short as possible Monitor s standard l...

Page 3: ...ce positioning In outdoor applications mount the box with the conduit openings facing down wards If installing with conduit be sure to provide a drip loop i e a section of conduit that is more then 6 lower then the box with a means to disperse any accu mulated water in the conduit so that water does not pour into the box Likewise if installing with cable and the cord connectors provided position a...

Page 4: ...l be used to eliminate shock hazard in the unlikely event of internal insulation breakdown Select wire size that can carry in excess of the sum of all circuit s maxi mum amperage EMI Optimizing See Figure 5 Ferrite beads are provided for installation in the wiring to minimize affects of EMI Wrap the large ferrite bead with the incoming power wires including protective earth con ductor two to four ...

Page 5: ...eet and where heavy electrical circuits motors contactors etc are not present The interconnection must be done point to point no multi dropping or networking with a 3 conductor cable such as Belden 9533 or Alpha 6303 Determine the type of connector on the PC source a suitable mating connector See Table 1 then intercon nect as described in Table 2 CONNECTOR TYPE AMPHENOL NORCOMP 9 pin D sub male co...

Page 6: ...gure 9 The RS 485 pro tocol permits network interconnection of multiple devices such as the control system SiloTrack sen sors SMUs Auxiliary Output Enclosures AOEs Remote Display Units RDUs and Wireless Communi cation Interfaces Devices on this network are inter connected in a daisy chain multi drop configuration using a 2 conductor shielded cable such as Belden 9322 or Alpha 6302 Order of connect...

Page 7: ...if the signal from the sensors SMUs is delivered to the Wireless Communication Interface via the wireless link This implies that the Wireless Communication Interface is on the control system side of the wireless link RS485 Select this if the signal from the sensors SMUs is delivered to the Wireless Communication Interface via RS 485 medium This implies that the Wireless Communication Interface is ...

Page 8: ...tch determines mode of operation RUN For normal operation of the Wireless Communi cation Interface set switch in this position TEST Use this selection for testing the radio link between Wireless Communication Interfaces Testing can be conducted with or without connection of the actual control system SiloTrack or sensors SMUs At the Wireless Communication Interface on the control system SiloTrack s...

Page 9: ...ata link is being influenced See above regarding occasional COM error 2 Verify radio channel selection Only 1 7 are valid TROUBLESHOOTING 3 Verify the master slave selection settings These settings can not be identical 4 Verify that the radio module is installed If a radio is not plugged into the main PCB a radio setting for master or slave will not be accepted PROBLEM The query LED is not strobin...

Page 10: ...y Two 2 0 88in 22 4mm dia holes Indicators Red LEDs Query Reply and Error Green LED Power Housing Powder coated die cast aluminum IP66 NEMA 4 Mounting Desk wall or pipe rail SPECIFICATIONS MECHANICALS Wireless Communication Interface Left Standard Antenna Center High Gain Antenna Right N to RP SMA Cable DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS General Safety CAUTION It...

Reviews: