Monicon Instruments Co., Ltd.
PCH-202
1、
Installation
1.
To prevent sparks during power up, please make sure the power switch is in off position
before plug-in the ac power cord.
2.
Connect positive and negative wires to the battery before switch the power to “ON”
position.
3.
PCH-202 is equipped with short circuit, over load, and reverses polarity protections.
4.
When the battery is below minimum charging voltage, charger ceases the output. Press
DC start button, PCH-202 starts charging regardless of battery voltage. If error LED
is ON, the overload or reverse polarity is present, please check the wire connections.
5.
The minimum charging voltage of a 24V battery must be greater than 6V, otherwise the
PCH-202 detects as battery error and cease the output. Press DC start to force charge
battery.
6.
PCH-202 automatically switches between float and equalized mode according to the battery
condition.
7.
Only supply AC input between 110V (90~130V)/220V(190~240V),50-60Hz, exceeding the range
might cause error or damage the charger.
8.
Avoid rain, sun light, dust, flammable material, and acidic gas.
9.
To maintain the best performance of the charger, please keep the environment between
-25℃ to 35℃, cooler the better.
10.
Please make sure the charger is installed in a well-ventilated area. To avoid bad
circulation and prolong the life of charger, keep at least 10CM between wall and
ventilation fan.