background image

- 3 - 

 

 

6 Configuration and Setup Of The Gateway PLUS........................................................................................... 22 

6.1  The Web Server .................................................................................................................................... 22 

6.1.1 Web Server Properties .................................................................................................................... 22 

6.1.2 Using the Security System ............................................................................................................... 23 

6.1.3 Using Services .................................................................................................................................. 25 

6.1.4 Using Electronic Mail ....................................................................................................................... 27 

6.2  Accessing the Virtual HMI .................................................................................................................... 32 

7 APPENDIX A – Gateway Serial Ports ............................................................................................................. 34 

8 Appendix B - SPECIFICATIONS ...................................................................................................................... 35 

 

Summary of Contents for CDL

Page 1: ...Monico Gateway from Cummins Version 1 03 Installation and Operation Guide Monico Inc 18530 Klein Church Road Spring TX 77379 281 350 8751 sales monicoinc com ...

Page 2: ...STS Status LED 12 4 3 Host Connections 13 5 MONICOVIEW II PROGRAMMER 14 5 1 USB Driver Installation 14 5 1 1USB Driver Troubleshooting 15 5 2 Window Layout 16 5 2 1The Navigation Pane 16 5 2 2The Resource Pane 16 5 2 3The Editing Pane 16 5 3 Obtaining Updating the Gateway Configuration 17 5 4 Setting the IP Address 17 5 5 Enabling TCP IP Download 18 5 6 Securing the Configuration Optional 19 5 7 A...

Page 3: ...LUS 22 6 1 The Web Server 22 6 1 1Web Server Properties 22 6 1 2Using the Security System 23 6 1 3Using Services 25 6 1 4Using Electronic Mail 27 6 2 Accessing the Virtual HMI 32 7 APPENDIX A Gateway Serial Ports 34 8 Appendix B SPECIFICATIONS 35 ...

Page 4: ...ons However any of our programs are modifiable using MonicoView II software Be sure to check the website for the latest software revisions before installation The major features are listed below Standard Version offers BACnet SNMP and Modbus TCP over Ethernet Serial interfaces on the above mentioned protocols can be provided using an optional serial interface card User Interface via a USB connecti...

Page 5: ... 5 Gateway Connection Overview Figure 1 ...

Page 6: ...g a file If this light is solid then a setup file is resident and operating Figure 2 CAUTION Reversing wire polarity may cause damage to your Gateway This damage is not covered by warranty If in doubt about which wire is which on your power supply check with a meter When using an external power supply it is very important that the power supply is mounted correctly if the unit is to operate reliabl...

Page 7: ...of Class 2 or SELV A Class 2 or SELV power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults SELV is an acronym for safety extra low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic ...

Page 8: ...th at one end where the unit is mounted o Connect the shield to earth ground at both ends of the cable usually when the noise source frequency is over 1 MHz o Connect the shield to common of the Data Station and leave the other end of the shield unconnected and insulated from earth ground Never run Signal or Control cables in the same conduit or raceway with AC power lines conductors feeding motor...

Page 9: ... in relation to cabinet orientation A minimum clearance of 1 inch 25 4 mm should be maintained above and below all units in order to ensure proper thermal regulation Also ensure that enough cable clearance is allowed at the front of the Gateway to allow cable connections to the Gateway s interface ports Figure 3 ...

Page 10: ...VDC 1 Amp power Supply Please review section 3 EMC Installation Guidelines before proceeding Locate and install the Monico Gateway and Power Supply to a DIN rail mount Ensure that the Cummins Modlon Gateway is mounted next to the Monico Gateway as shown in Figure 4 Plug the RJ12 connection end of the serial cable into the Monico s RS232 port and the DB9 end into the top of the Modlon Gateway Conne...

Page 11: ...ater as shown in figure 3 Using Belden 984x or equivalent communication cabling connect the Repeater to the controller as shown in Figure 5 noting that the shield should ONLY be connected at the controller end Set the dip switch settings on both the top and bottom ports of the Isolated Repeater as shown in Figure 5 By default the Monico Gateway is set to communicate with the Controller via Modbus ...

Page 12: ... 2 3 TCP IP Ethernet Port LEDs These LED s are the first step in troubleshooting communications issues Please note the action of these LED s IN DETAIL when contacting the Monico for technical support LED Indication Rapidly Flashing Gateway is currently loading program Steady Gateway is operating normally LED Indication Green Transmitting Red Receiving LED Indication Yellow Solid Link Established Y...

Page 13: ...d or serially as an option The above mentioned protocols can be established at either 10 BASE T or 100 BASE TX The Gateway s RJ45 jack is wired as a NIC Network Interface Card For example when wiring to a hub or switch use a straight through cable but when connecting to another NIC use a crossover cable Default IP Address is 192 168 1 10 As stated the default Monico Gateway protocols include Modbu...

Page 14: ...hould occur contact Monico and we can send a copy of the file supplied with the Gateway Please make note the Version Number on the label on the right side of the Gateway so we can identify the appropriate file Whenever upgrading MonicoView II Programmers versions us the REPAIR option The connection is established through a standard USB printer cable that has a rectangular connector on one end and ...

Page 15: ...puter s ground is not referenced to the same ground as the Gateway To resolve this simply unplug your computer from the AC power source during programming and update operations Depending on the administrative rights of your computer the USB driver may not install correctly the first time the driver is installed This will be evident if a USB connection cannot be made to the Gateway The following st...

Page 16: ... the window is called the Navigation Pane It is used to move between different categories of items within a MonicoView II configuration file Each category is represented by a bar at the base of the pane and clicking on that bar will navigate to that section The top section of the Navigation Pane shows the available items in the current category and provides a toolbar to allow those items to be man...

Page 17: ...ny changes made will need to be downloaded to the Gateway before taking effect To upload changes simply select Link Update from the menu Setting the IP Address By default the IP parameters of the Gateway are set to the following o IP Address 192 168 1 10 o Network Mask 255 255 255 0 o Gateway 0 0 0 0 You can easily change these to whatever you wish by performing the following steps Make sure you h...

Page 18: ...II software than what it was originally programmed with Keep in mind that you must first use the USB connection to set the Gateway to the required IP parameters as described in section 5 4 Setting the IP Address You must also ensure that Remote Update is enabled and that the Port number is set to 789 as shown in Figure 11 Once the above mentioned has been performed over USB you may perform databas...

Page 19: ... enabled on all Monico configurations however if you choose to have Support Upload disabled and lose your database file you will not be able to reconstruct your file without starting from scratch It is therefore IMPERATIVE that a Master Copy be properly maintained when Support Upload is disabled Adjusting Serial Port Settings By default the Monico Gateway has three serial ports including two RS 23...

Page 20: ... area of the Editing center pane Note that when the device is disabled a red X will appear over the device as shown in Figure 13 Figure 13 Viewing Live Real Time Data MonicoView II supports Live Data viewing within a Watch Window that allows you to see the actual data acquired by the Monico Gateway in real time This is a great trouble shooting aid in determining what values are being acquired by t...

Page 21: ... begin showing live data according to the appropriate format of the object If the Gateway is successful in acquiring the data from the end device it will show the value in real time If the Gateway is NOT able to acquire the data from the end device it will show n a in the dialogue box as shown in Figure 15 Figure 14 Figure 15 ...

Page 22: ...MonicoView II provides a variety of protection mechanisms to limit access to the web server you should use good engineering practices when designing your system This means that you should avoid performing any safety related operations via the web server and you should ideally use an external firewall to prevent unauthorized access in case MonicoView II s own security protections are breached Secur...

Page 23: ...ess matches the mask and data indicated All access may be restricted or the filter may be used to restrict just the remote control or data editing facilities The Authentication group defines whether users connecting to the web server will be required to provide username and password information and how that information will be validated The Method defines the algorithm to be used with Digest being...

Page 24: ...ation List Figure 17 The Real Name property is used to record the user s identity in security logs and is also shown in the Security Manager primitive that is used to change passwords at runtime If maximum security is required the user name should not be easily derived from the real name The Password property specifies an initial password for this user The password is case sensitive and comprises ...

Page 25: ...tion methods are all designed to work with Universal Coordinated Time also known as UTC or Greenwich Mean Time 6 1 3 1 1 Configuring the Service The Time Manager is configured via the associated icon in the Navigation Pane Figure 18 The Enable Time Manager property is used to control access to the other facilities If it is not checked default MonicoView II will operate in the local time zone only ...

Page 26: ...ou have several MonicoView II devices on the same network though you will find it better to nominate one of these as the master device for the purpose of setting Daylight Savings Time and then have that device alone synchronize to the enterprise time source You can then configure the other devices to synchronize to the master device and enable the Linked DST facility to propagate the Daylight Savi...

Page 27: ... back A typical database will only need to expose UseDST for editing by the user and even this may not be necessary if the Linked DST facility described above is in use 6 1 4 Using Electronic Mail MonicoView II can be configured to send email messages when alarm conditions are present or when notifications need to be provided of other events within the system The mail transports and the email addr...

Page 28: ... to be entered The address should be in a format suitable for the required transport For example SMTP names should be in the usual name domain format while SMS names should be entered as international format telephone numbers without the leading plus sign Multiple email addresses can be entered by separating them by semicolons allowing simple mailing lists to be created ...

Page 29: ... can be enabled Note also that at least one transport must be enabled if the mail manager is to be able to deliver messages The Server Selection property defines how the transport will locate an SMTP server If Manual Selection is used the Server IP Address property should be used to manual designate a server If Configured via DHCP is selected at least one Ethernet port must be configured to use DH...

Page 30: ...TP server to send its welcome banner Some Microsoft servers attempt to negotiate Microsoft specific authentication with mail clients thereby delaying the point at which the banner appears You may want to extend this time period to 2 minutes or more when working with such servers The Record Log File property can be enabled to keep a log of all SMTP interactions in the root directory of the CompactF...

Page 31: ...has the following properties pertinent to notifications on its Alarms tab The Event Mode property is used to indicate the logic that will be used to decide whether the alarm should activate The tables below list the available modes Mode Alarm will activate when Active On The tag is true Active Off The tag is false Change of State The tag state has changed The Event Name property defines the name t...

Page 32: ... or event this property also specifies the amount of time for which the alarm condition must no longer exist before subsequent re activations will result in a further alarm being signaled The Accept property is used to indicate whether the user will be required to explicitly accept an alarm before it will no longer be displayed For messaging notifications this should always be set to Automatic The...

Page 33: ... 33 Figure 24 ...

Page 34: ...s RS 485 RS 422 Connections RS 485 RS 422 Schematic Please note that different companies use different terminology For example some use TxA and TxB to describe 2 wire RS 485 connections Some use Tx and Tx In general TxA Tx and TxB Tx For 2 wire RS 485 use Pin 7 and Pin 8 ...

Page 35: ...ge Temperature Range 30 to 70 C Operating and Storage Humidity 80 max relative humidity non condensing from 0 to 50 C Vibration According to IEC 68 2 6 5 to 150 Hz in X Y Z direction for 1 5 hours 2 g s Shock According to IEC 68 2 27 Operational 30 g 11 msec in 3 directions Altitude Up to 2000 meters CONSTRUCTION Case body is black high impact plastic and stainless steel Installation Category I Po...