27D8520
21
ON
OFF
PIILO
T
OPERATING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. Turn gas control knob clockwise
to the “OFF” position, and turn ON/OFF switch to
“OFF” position.
4. Wait (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell
gas, STOP!
5. From “OFF” position, turn the gas control knob counterclockwise
to “PILOT” position.
Push in control knob for 5 seconds.
6. With the control knob pushed in, light pilot with match.
7. Continue pushing the control knob in for a further 60 seconds to prevent the fl ame detector from
shutting off the gas while the probe is warming up. Release the control knob.
8. Turn gas control knob counterclockwise
to the “ON” position.
9. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF
switch to “ON” position.
10. If the gas logs will not operate, follow the instructions
“To Turn Off Gas to Heater”
and call your
service technician or gas supplier.
Figure 31 - Control Knob
Figure 30 - Pilot
TO TURN OFF GAS TO HEATER
1. Turn control knob clockwise
to OFF position to completely shut off the heater.
2. If applicable: Turn ON/OFF switch to OFF position.
MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
Figure 32 - On/Off Switch