19
VFF Vent Free Fireplace System
Monessen • VFF 32/36 Owner Manual • 20308184 • Rev F • 02/19
ELECTRICAL WIRING
General
This fireplace is equipped with an IPI control valve which
operates on 6 volts. The 6 volt DC adapter plugs into the
fireplace junction box A/C power supply.
It is equipped with a battery back-up which will operate
the unit for approximately 48 hours in the event of a power
failure using on/off function only. Use of high/low function
will reduce battery life while in back-up mode.
Optional Accessories
This fireplace may be used with a wall switch, wall mounted
thermostat or IPI hand held remote control.
CAUTION
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
ELECTRICAL INSTALLATION — IPI
WARNING: Electrical connections should
only be performed by a qualified, licensed
electrician. Main power must be off
when connecting to main electrical power
supply or performing service. All wiring shall
be in compliance with all local, city and state
codes. The appliance, when installed, must be
electrically grounded in accordance with local
codes or in the absence of local codes, with
the National Electrical Code ANSI/NFPA 70
(latest edition) and Canadian Electrical Code,
CSA C22.1.
FP1912
Junction box wiring
8/08
Junction Box
Factory Supplied
Not Supplied
120V AC
60Hz
WARNING: Do NOT connect to a
110V circuit.
JUNCTION BOX WIRING
1. This should be done before framing the fireplace. Wire
the receptacle into an electrical circuit. Wire with mini-
mum 60° C wire in accordance with prevailing codes.
2. Remove the external junction box cover by removing
the screw from the side of the outside firebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed “romex”
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to
the wiring diagram in Figure 20
Figure 19.
BLOTMC Blower Wiring Diagram
OPTIONAL FORCED AIR KIT (BLOTMC)
If you are installing the forced air blower kit, refer to the
installation instructions provided with the kit. The firebox
must be connected to main power supply at time of fire-
box installation. The electrical connections must be made
before the firebox is framed and enclosed in the finished
walls.
BLACK
BLACK
WHITE
GREEN
BLACK
BLACK
WHITE
Receptacle
Junction
Box
120VAC
Speed Control
FP2675
BLOT blower wiring
Figure 20.
Junction Box Wiring Diagram