26D4720
7
MINIMUM HEARTH DIMENSIONS
GENERAL INSTALLATION INFORMATION
AND
LOCATION OF FIREBOX
Figure 2 - Minimum Hearth Dimensions
LOCATION OF FIREBOX
Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and
windows. See “Clearances/Height Requirements on
page 8. Minimum clearances to combustibles
must
be maintained.
• Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows
or doors.
• Installation must provide adequate ventilation and
combustion air.
•
DO NOT INSTALL THIS FIREBOX IN A
BEDROOM OR BATHROOM.
• Location should be out of high traffic or windy or
drafty areas.
•
DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS
ARE LESS THAN 42" FROM FRONT OF HEATER.
• Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation air.
• Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox must be
kept clear and free from these combustible materials.
Figure 3 - Location of Firebox
MCUF36D-F MCUF36D-R MCUF42D-F MCUF42D-R
A
26
1
/
4
" 25
3
/
4
" 32
1
/
4
" 31
3
/
4
"
B
15" 14
3
/
4
"
15" 14
3
/
4
"
C
32
5
/
8
" 32
1
/
8
" 38
5
/
8
" 38
1
/
8
"
D
25" 25" 25" 25"
E
20
1
/
2
"
20
1
/
2
" 20
1
/
2
" 20
1
/
2
"
Summary of Contents for Magnum Unvented Vent-Free Fireboxes MCUF36D
Page 19: ...26D4720 19 NOTES ...