27
75D2523
MDV Series Direct Vent Gas Fireplace
flex VentIng InstallatIon
4" x 7" flex pipe
If you prefer to use 4" x 7" flex pipe, you must install model
7TDVP58 reducer (5" x 8" to 4" x 7") onto the fireplace
collar. Then follow the assembly guidelines for 5" x 8" flex
venting.
Termination
Cap
Storm Collar
Roof Support
Flashing
Rigid Pipe
Length
Flex to Pipe
Adapter
(DVFFA/8)
Firestop
UL1777 Flex
PIpe
Figure 42 -
Typical Vertical Flex Vent Installation
FP1975
4 x 7 pipe connection
Screws
(3 Places
equidistant
just above
gear clamp)
4" x 7" Rigid Pipe Length
Flex to Pipe Adapter
(DVFFA/8)
Gear Clamp
1
C\v
" Flexible Pipe and Adapter
Outer Collar Overlap
UL1777 Flex Vent
Figure 43 -
Typical Pipe Connection
Gear
Clamp
FP1976
horizontal flex
Screws
(3 Places equidistant just
above gear clamp)
Gear Clamp
UL1777 Flex Vent
1
C\v
" Flexible Pipe and
Collar Overlap
MHSC Horizontal
Vent Termination
Figure 44 -
Typical Horizontal Flex Vent Installation
7TDVP58 5" x 8" to
4" x 7" Reducer
FP1974
FP1972
appliance connection
UL1777
Flex Vent
Screws
(3 places,
equidistant just
above gear
clamp)
1
C\v
" Flexible
Pipe and Adapter
Outer
Appliance
Starting Collar
Figure 41 -
Typical 4" x 7" Appliance Connection
5" x 8" to 4" x 7"
Adapter (7TDVP58)
Gear
Clamp
FP1972a