9
CFX Vent Free Fireplace System
20301726
FP2110a
fireplace locations
12/08
Carefully select the best location for installation of your unvented fireplace. The following factors should
be taken into consideration.
•
Clearance to side wall, ceiling, woodwork and window or other combustibles. Refer to
Clearances
and
Height Requirements
section on
Page 10.
Minimum clearances to combustibles
must be main-
tained.
•
Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air reg-
isters for forced air furnaces/air conditioners, windows or doors.
•
Installation must provide adequate ventilation and combustion air.
•
DO NOT INSTALL THE CFX MODEL IN A BEDROOM OR BATHROOM.
•
Location should be out of high traffic areas and away from furniture and draperies due to heat from
firebox.
•
Never obstruct the front opening of the unvented fireplace or restrict the flow of combustion and
ventilation air.
•
Do not install in the vicinity where gasoline or other flammable liquids may be stored. The unvented
firebox must be kept clear and free from the combustible materials.
Figure 4 -
Suggested Locations
FP2110a
FIREPLACE INSTALLATION