MAINTENANCE AND CLEANING
NOTE:
The rear porcelain panel is held in place by
the left and right panel and could fall forward if not
supported during removal of the side panels.
5. With side panels removed the rear porcelain panel
can be removed from the unit and placed on a clean,
level surface.
6. Remove nine screws that secure the front hearth in
place and remove from unit.
Figure 42
7. Figure 43 shows bulb placement for front and rear
light bars. Insert bulbs in sockets.
8. With (twelve 20W) bulbs installed in front and rear
light bar, reinstall the rear hearth first with five
screws that were removed earlier.
Figure 42
9. Reinstall the front hearth with nine screws removed
earlier.
Figure 42
10. Place the rear porcelain panel back in place and
reinstall the left and right side using same screws
that were removed earlier. Replace the retainer clips
at bottom of porcelain panels.
11. Re-install the air deflection glass and decorative
media (see page 17).
Retainer clip
Porcelain
panel screw
Nine Front Hearth Screws
Five Rear Hearth Screws
Figure 41–
Porcelain Panel Retainer Clip Location
Figure 40–
Porcelain Panel Screw Location
Figure 42–
Hearth Screw Locations