6
AVFL Vent Free Fireplace
Monessen • AVFL42NTSC-SR Installation Instructions • 4116-900 Rev. B • 10/19
PRODUCT FEATURES
GAS PRESSURES
GAS SPECIFICATIONS & ORIFICE SIZE
AVFL42 CONTROLS
MODEL
FUEL
INPUT
(BTU/h)
ORIFICE
SIZE
AVFL42NTSC-SR
NAT.
24,500
#50
NATURAL
Inlet Minimum
5.0" w.c.
Inlet Maximum
10.5" w.c.
Regulator Pressure
Setting
3.5" w.c.
Pilot Regulator
3.5" w.c.
FP3020
AVFL controls
Control Board
FP3020
Thermocouple
Module
Command Center
AC Module
Figure 1 –
AVFL42 Controls (Control Access Door Shown Open)