Monark 891 E/891 E Wingate Option
13
Troubleshooting guide 891 E Wingate Option
Symptoms
Probable Cause/Corrective Action
There is a click noise with every pedal
revolution (increases with the weight).
The pedals are not tight. Tighten them or change pedals.
•
The crank is loose. Check, tighten.
•
The base bearing is loose. Contact your dealer for service.
•
Scratching sound is heard when pedalling. Check that the carriage block is taken off and that none of the covers is
scratching.
There is a click noise and a squeak noise
when pedalling.
Loosen the chain.
The display is not working.
Check that the batteries are OK.
Timekeeping does not start.
Check if the brake belt is to tight so the magnet will not pass the sensor.
This will result in no signal from sensor. There is a video available of
website www.monark.net which describe adjustment.
Bike would not start.
Weight basket does not lock in upper
position.
Power adaptor is not connected.
•
Main switch is not in ON position. Located on bikes right side
•
underneath tension devise.
The power jack is not functioning, the fuse is blown.
•
Incorrect type of power adaptor is used. A marking label should be
•
found with the text ”Peak bike 894 E”.
Power adaptor is broken and needs to be replaced.
•
The yellow LED lamp will not light up
when the weight basket is hoisted up
(should light within 2-3 seconds after the
basket been hoisted up).
Check that magnets on both side of tension device has not fallen off
•
and without damages.
Check so basket lock sensor and basket drop sensor is working
•
properly and also connected to correct ports on bikes circuit board. See
fig: Connections on Circuit board.
Problems with the sensors.
Technical advice how to check sensors of magnetic type:
1. Unplug the sensor on bikes circuit board.
2. In the jack in the end of sensor cable measure with a summer or an
ohmmeter then angle the magnet in near of the sensor. A signal should be
heard or value approx. 0 ohm displayed on ohm meter.
No heart rate displayed
Check the chestbelt (battery). Wet the thumbs and place them on the
•
electrodes. A low clicking sound will appear near battery lid while you
click on the electrodes with one thumb.
Check that the chestbelt is positioned correct on test person and tight
•
enough. Check that the electrodes are wet. In hard cases it is necessary
to use a contact gel or a mixture of water with a few drops of washing-
up liquid. The level for HR signal can vary from person to person. Put
chestbelt on another known person who has a good pulse rendering.
Uneven heart rate.
Use an external unit for example a HR watch to check if it also indicates
irregular pulse. If this is the case, there is probably disturbance in the room.
Magnetic fields from high voltage cables, elevators, fluorescent tube etc.
can cause the disturbance. Other electronic equipment could be placed too
close. Move the bike to a different location in the room or change rooms. If
an irregular HR remains it should be checked manually If the HR remains
irregular at work the person's health should be examined.
The weight basket moves up and down.
The brake belt contact surface may need to be ground off. See description
in section “Brake belt contact surface”.
The weight basket touch the flywheel.
The brake cord is probably not enough tightened. The basket can be loaded
with a lot of weight. Tighten the brake cord. See the section "Adjustment
brake cord tension".
According to test the bike seems to give
too high workload.
The brake cord may be too tighten. Loosen the cord according to section
“Adjustment brake cord tension”.