Nova-Strobe Battery Replacement

for models: Nova-Strobe BBX, Nova-Strobe DBX, and Phaser Strobe PBX, Vibration Strobe VBX

Taking the unit apart is the easy part . . .

 

To do this, [A] remove the lens by 

separating the two tabs that hold 

it in place. Put a piece of tape on 

the side of the lens that faces out 

so it can be installed correctly. Slide 

the re

fl

 ector [B] and lamp out as 

detailed in the Lamp Replacement 

section of your manual. This will 

expose four screws [C] that must 

be removed so the re

fl

 ector  hous-

ing can be removed from the main 

body. There are then four additional 

screws [D1] & [D2] in the case 

halves opposite the input and 

output jacks that must be removed. 

The case halves can now be separated, 

exposing the batteries. They  should 

be sent to a recycling center or 

returned to Monarch for disposal.

Before you open the case, know that during the reassembly there are multiple points that 

need to align correctly to close the case securely. 

Some of them include:

• 

Display board sits in groove 

• 

DC Connector spans both case halves

• 

Mounting T-nut sits in slot as shown

• 

Lanyard knot surrounds screw standoff and protrudes through the notch in the case

• 

Trigger sits in case brackets with wires tucked out of the way

• 

PCB aligns in a retaining groove

• 

Battery holders (2) nests in brackets, there is a right and wrong way to insert them

[A]

[B]

[C]

[D1]

[D2]