SUPPLY OUT -
is soft water supply back to property
f
TO UNIT-
is mains hard water from bypass to softener inlet via flexi hose
+
FROM UNIT -
is soft water from the softener outlet back to bypass via flexi hose
Every standard Rapid-Fit bypass comes with the following;
a.
2 Max flow hoses
b.
2no 24.6mm fibre washers
c.
2no 22mm x ¾" Fl brass adaptors
d.
2no 22mm x 15mm reducers
This unit comes with Maxflow hoses as standard - see picture right. For 22m
do not use the 22mm x 15mm reducers.
For 28mm applications, upgrade to 1". Code is PS28UG HE if ordered with softener. For upgrade after softener
order, code becomes PS28UGLOHE.
I
Connection of brass adaptor (22x¾FI & 28x1"FI) to Rapid-Fit bypass:
� �
-
b�:-�
·
·
·
1.
Fibre washers are pre inserted against shoulder inside brass femaled thread- Fig 1.
IMPORTANT - Do not use 3/4" industry standard washers here.
2.
For additional security, Fernox LS-X or Loctite SI 5331 may be used. Simply apply to male thread of noryl
bypass adaptor and to inside of female thread of brass fitting - Fig 2. In all cases, fibre washer must be used
3.
Tighten male noryl connection into brass adaptor solidly up against fibre washer- Fig 3. Remove any
excess
sealant inside brass/noryl adaptor assembly
4.
Place assembled connection back into bypass and fix with clip - Fig 4
5.
Run hard water mains supply pipe to SUPPLY IN connection - Fig 5
6.
Repeat 1-5 above for soft water mains supply to SUPPLY OUT connection
IMPORTANT: Noryl bypass adaptor is an 'o' ring seal within main bypass body, therefore it may be easier
to
connect brass fitting to adaptor if adaptor is
remote from bypass
.
To remove adaptor, simply remove holding dip. Do not use heat on any connection that may affect the bypass.
Fig 1
Fig 2
Fig 3
Fig 4
Fig 5
Monarch Water Ltd
T: 01986 784759
monarchwater.co.uk [email protected]
20
�
,.
�
Rapid-Fit bypass installation instructions.
Directional arrows are embossed on the bypass as follows.
f
SUPPLY IN -
is hard water supply in from mains