10
3.5 Mode Selection
The
INPUT
button, shown right, toggles between the
INTERNAL and EXTERNAL Modes as described in Section
1.2. When in the external mode the display will show
EXT
and the stroboscope will only flash with an external input. Plugging
in an external source will cause the unit to automatically switch to the
EXTERNAL mode. Removing an external source while in the EXTERNAL
mode will cause the unit to switch to the INTERNAL mode.
3.6 Memory
The Stroboscope has the ability to save and recall up to 5 values.
This is done by pressing the
MEM
ory button shown right. The
first time the button is pressed the display will show
READ
, if
pressed again it will show
SAVE
. If the knob is turned while
READ
or
SAVE
is displayed, the display will cycle through memory locations 1
to 5 (indicated as
RM1
to
RM
5
where RM is Recall Memory or
SM1
to
SM
5
where SM is Save Memory). To actually SAVE or READ the selected
memory location, press the
MEM
button again. The
ENTER
button works
as well. The display will show
DONE
. Note that the value saved will be the
current flash rate prior to pressing the
MEM
button the first time.
3.7 Phase Delay
The
DELAY
button adjusts the phase shift of the flash with
respect to time. There are two modes: INTERNAL and
EXTERNAL (PBL model only).
3.7.1 Internal Phase Delay
Also referred to as JOG. Once the flash rate has been adjusted to give
a stopped motion image, the PHASE
DELAY
button may be used to
increase or decrease the phase of the image with respect to its original
position. Use the PHASE
DELAY
button to bring a reference mark,
such as a key way, into your line of sight.