background image

3

GROUP-B

GROUP-A

PA LINE CURRENT MONITORING UNIT

AMP 1

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

AMP 2

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

AMP 3

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

AMP 4

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

SPARE AMP

IN

AMP FAULT

AMP 1

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

AMP 2

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

AMP 3

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

AMP 4

GROUND
FAULT

RESET

AMP FAULT

SIG LEVEL

0

10

PA-24AFE

FAULT SIGNAL

SPARE AMP

IN

AMP FAULT

FAULT SIGNAL

POWER

BUZZER OFF

GROUND FAULT

INDICATION OFF

4 5

6

7 8

9

10

SPEAKER

OUTPUT

B

SPEAKER

OUTPUT

B

230 V~ / 50 Hz / 20 VA

FUSE RATING  T 0.5AL 250 V

DC POWER

4

24 V MAX 0.6 A

GROUP-B

SPARE AMP

GROUP-A

SPARE AMP

G

G

INPUT

AMPLIFIER

SIGNAL
INPUT

G

G

INPUT

AMPLIFIER

SIGNAL
INPUT

4

GROUP-B

3

2

1

4

GROUP-A

3

2

1

SPARE AMPLIFIER

EXTENSION FAULT SIGNAL OUT

14

15 16

17

18

19

1

2

3

11

12

13

SPEAKER

OUTPUT

B

SPEAKER

OUTPUT

B

230 V~ / 50 Hz / 20 VA

FUSE RATING  T 0.5AL 250 V

DC POWER

4

24 V MAX 0.6 A

GROUP-B

SPARE AMP

GROUP-A

SPARE AMP

G

G

INPUT

AMPLIFIER

SIGNAL
INPUT

G

G

INPUT

AMPLIFIER

SIGNAL
INPUT

4

GROUP-B

3

2

1

4

GROUP-A

3

2

1

SPARE AMPLIFIER

EXTENSION FAULT SIGNAL OUT

Signaleingang

Signal input

(Line)

Signaleingang

Signal input

(Line)

Lautsprecherausgang
Speaker output
(100 V)

POWER

PA-1122   

PA POWER AMPLIFIER

10

0

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

CLIP

-13

0

-3

-8

TEMP

PROT

PWR

LEVEL

POWER

PA-1122   

PA POWER AMPLIFIER

10

0

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

CLIP

-13

0

-3

-8

TEMP

PROT

PWR

LEVEL

Signaleingang
Signal input
(Line)

Lautsprecherausgang

Speaker output

(100 V)

Reserveverstärker der Gruppe A
Spare amplifier of the group A

PA-25AFE

Verstärker 4
Amplifier 4

100 V

+

-

Lautsprecherlinie 4

Speaker line 4

100 V

+

-

Lautsprecherlinie 3

Speaker line 3

100 V

+

-

Lautsprecherlinie 2

Speaker line 2

100 V

+

-

Lautsprecherlinie 1

Speaker line 1

POWER

PA-1122   

PA POWER AMPLIFIER

10

0

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

CLIP

-13

0

-3

-8

TEMP

PROT

PWR

LEVEL

Verstärker 3
Amplifier 3

POWER

PA-1122   

PA POWER AMPLIFIER

10

0

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

CLIP

-13

0

-3

-8

TEMP

PROT

PWR

LEVEL

Verstärker 2
Amplifier 2

POWER

PA-1122   

PA POWER AMPLIFIER

10

0

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

CLIP

-13

0

-3

-8

TEMP

PROT

PWR

LEVEL

Verstärker 1
Amplifier 1

Signaleingang
Signal input
(Line)

Lautsprecherausgang
Speaker output
(100 V)

Signaleingang
Signal input
(Line)

Lautsprecherausgang
Speaker output
(100 V)

Signaleingang
Signal input
(Line)

Lautsprecherausgang
Speaker output
(100 V)

Anschlussbeispiel für die
Verstärkergruppe A

Connection example for
the amplifier group A

Summary of Contents for PA-24AFE

Page 1: ...E D EMPLOI ISTRUZIONI PER L USO CONSEJOS DE SEGURIDAD INSTRUKCJA OBSLUGI VEILIGHEIDSVOORSCHRIFTEN SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDESTA ELA LINIENSTROM BERWACHUNG PA LINE CURREN...

Page 2: ...zna wszystkie funkcje tego urz dzenia Stosuj c si do instrukcji unikn pa stwo b d w i ewentualnego uszkodzenia urz dzenia na skutek nieprawid owego u ytkowania Tekst polski znajduje si na stronach 10...

Page 3: ...INPUT AMPLIFIER SIGNAL INPUT 4 GROUP B 3 2 1 4 GROUP A 3 2 1 SPARE AMPLIFIER EXTENSION FAULT SIGNAL OUT Signaleingang Signal input Line Signaleingang Signal input Line Lautsprecherausgang Speaker out...

Page 4: ...s Tuch niemals Wasser oder Chemikalien Wird das Ger t zweckentfremdet falsch ange schlossen bzw bedient oder nicht fachgerecht re pariert kann keine Haftung f r daraus resultie B Please unfold page 3...

Page 5: ...plant for a disposal which is not harmful to the environment Important for U K Customers The wires in the mains lead of the power supply unit are coloured in accordance with the following code green y...

Page 6: ...ter POWER 8 nicht ausschalten Es wird lediglich zwischen Netz und Notstromversorgung umgeschaltet Das Ger t geht in Betrieb sobald es ber die Notstrom versorgung gespeist wird 6 Bedienung 1 Im Normalb...

Page 7: ...7 Blockschaltbild Block diagram...

Page 8: ...ebruik bin nenshuis Vermijd druip en spatwater uitzonder lijk warme plaatsen en plaatsen met een hoge vochtigheid toegestaan omgevingstemperatuur bereik 0 40 C Plaats geen bekers met vloeistof zoals d...

Page 9: ...eikat T m laite soveltuu vain sis tilak ytt n Suojele laitetta kosteudelta vedelt ja kuumuudelta sal littu ymp r iv l mp tila 0 40 C l sijoita laitteen p lle mit n nestett sis l t v kuten vesilasia tm...

Reviews: