1  Control Elements 

and Connections

1.1  Mixing  amplifier  PA-2410Z / 2420Z

Cover of the insertion compartment;  

 

an insertion module from MONACOR can 
be installed here, e . g . tuner, CD player, 
message storage module

Volume controls, one each for the input 
channels  1 – 5 
Control 1 can also be used to adjust the 
volume for the desk microphones PA-
4300PTT .
Control 2 can also be used to adjust the 
volume for the zone paging microphones 
PA-2400RC . (Exception with the PA-2410Z: 

 chapter 8 .7 .1)

Bass controls and treble controls to adjust 
the sound, one each for the input chan-
nels  1– 5

Bass control and treble control to adjust 
the tone of the insertion module

Button CHIME to trigger the chime

Control to adjust the volume of the chime

Control TEL PAGING to adjust the volume 
of a signal source at the input terminals 
PAGING IN (24) 

Control to adjust the volume of the siren

Buttons to switch the siren tones on and 
off

  

repeated wailing, (tone rising and 
falling)

   rising tone followed by continuous 

tone

10 

LED indicator PROTECT; will light up in case 
of an amplifier failure (e . g . due to overload 
or overheating)

11 

Control MASTER to adjust the total volume

12 

LED indicators
STAND-BY:  standby mode
POWER:    operating mode

13 

POWER switch

14 

PA-2420Z only:

Zone selection buttons
Z1 – Z20:  zones  1– 20
ALL:   

 all zones of the corresponding 
row of buttons 

 

When the button is pressed 
again (for 2 seconds), the previ-
ous selection will apply .

15 

Output level indicator
CLIP:  Overload indicator

16 

PA2410Z only:

Volume selection switches, one each for 
the zones 1–10
OFF:  Zone off

17 

Mains connection cable for connection to 
a  socket  (230 V/ 50 Hz)

18 

Plug-in screw terminals (removable) for the 
100 V speakers of the zones 1–10 or 1– 20 

Important:

 Each output can only be loaded with 

an RMS power of max . 60 W (PA-2420Z) or 30 W 
(PA-2410Z) . The total load of all 100 V speakers 
connected must never exceed 240 W . 

19 

Screw terminals AC POWER REMOTE to 
switch the amplifier on and off by remote 
control via a normally open contact

20 

Screw terminals DC POWER for emergency 
power supply (

  24 V))

21 

Plug-in screw terminals LOW IMP for a 
low-impedance speaker with a minimum 
impedance of 4 Ω , regardless of the zone 
selection

Important:

 Never use this output simultaneously 

with the 100 V outputs (18, 22); the amplifier may 
be overloaded .

22 

Plug-in screw terminals HIGH IMP to con-
nect 100 V speakers, regardless of the zone 
selection

Important:

 The total load – load at this output 

plus the total load by the speakers at the zone 
outputs (18) – must never exceed 240 W; other-
wise, the amplifier may be overloaded .

23 

Fuse for the 24 V emergency supply unit
Always replace a blown fuse by one of 
the same type!

24 

Plug-in screw terminals PAGING IN to con-
nect a signal source with line level out-
put for announcements of higher priority 
(

 table in fig . 5 in chapter 3)

25 

Plug-in screw terminals E / M MESSAGE 
CONTROL for connection of a normally 
open contact to trigger an announce-
ment (e . g . emergency announcement) 
when a message storage module (e . g . 
PA-1120DMT) is installed .

26 

6 .3 mm jacks PRE OUT and AMP IN to in-
sert an audio processing unit, for example 
When the jack AMP IN is used, the internal 
signal connection to the power amplifier 
will be interrupted .

27 

Connections REC (RCA jacks) for a recorder
L (left) and R (right) jacks are provided 
for stereo recorders . Since the amplifier is 
monophonic, the signals at the two jacks 
are identical .

28 

Inputs LINE IN (RCA jacks) for the chan-
nels 4 and 5; L (left) and R (right) jacks are 
provided for stereo signal sources . Since 
the amplifier is monophonic, the stereo 
signals are internally combined to a mono 
signal .

29 

Inputs for microphone level and line level 
(combined XLR / 6 .3 mm jack), balanced; 
one input each for the input channels 1– 3

30 

Controls GAIN to match the input gain 
with the signal source (microphone level 
to line level); one control each for the input 
channels  1– 3

31 

Switches PHANTOM POWER, one each 
for the input channels 1– 3; when the 
switch is engaged, a DC voltage of 15 V 
for phantom-powered microphones will 
be available at the XLR contacts of the 
corresponding input jack (29)

Caution:

 To prevent loud switching noise, use the 

switch only when the amplifier has been switched 
off, the outputs have been muted or the control 
MASTER (11) has been set to “0” . Do not connect 
any microphone (or other type of signal source) 
with unbalanced signal output when phantom 
power has been activated; otherwise, the mi-
crophone (or other type of signal source) may 
be damaged .

Contents

Control Elements and Connections

    12

11  Mixing  amplifier  PA-2410Z / 2420Z          12
12  Desk microphone PA-4300PTT              13
13  Zone paging microphone PA-2400RC

   .   .   13

Safety Notes

                              14

Applications and Accessories

          14

Selecting the Chime Melody

            14

Priority of the Insertion Module

        14

51  PA-2400RC: Locking message M6           15

Setup Options

                            15

61  Rack installation                             15

Establishing Connections

                15

71 Speakers                                    15
711 

Output LOW IMP                        15

72  Mono audio sources, microphones           15
721 

Phantom power supply                  15

722 

Defining priority                         15

723 

Paging input                            15

73  Stereo audio sources                        16
74  Desk microphone PA-4300PTT              16
75  Zone paging microphone PA-2400RC       16
751 

Setting unit addresses                   16

76  Recorder, monitor system                    16
77  External signal processing                  16
78  Switching inputs                            16
781 

Remote-controlled switch-on 
and switch-off                          16

782 

Alarm input                              16

79  Power supply and 

emergency power supply                    17

8 Operation

                                 17

81  Switching on/off                             17
82  Selecting the PA zones                      17
821 PA-2420Z                                17
822 PA-2410Z                                17
83  Setting the input channels                   17
84  Triggering the chime                         17
85 Siren                                        17
86  Desk microphone PA-4300PTT              17
861 

Settings at the PA-4300PTT              17

87  Zone paging microphone PA-2400RC       18
871 

Additional amplifier in the PA-2410Z    18

872 

Zone output group                       18

873 

Additional settings at the PA-2400RC     18

Protective Circuits and 
Fault Indication

                          18

10 Specifications

                            19

101 Amplifier                                    19
102  Zone paging microphone PA-2400RC       19
103  Desk microphone PA-4300PTT              19

English

English
English Page
Contents

Block diagram

                                62

Summary of Contents for PA-2400RC

Page 1: ...ISTRUZIONI PER L USO GEBRUIKSAANWIJZING MANUAL DE INSTRUCCIONES INSTRUKCJA OBS UGI SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDESTA ELA Mischverst rker PA Mixing Amplifier PA 2410Z Bestel...

Page 2: ...50Hz MASTER P A PRE OUT AMP IN LINE IN L R 5 4 2 1 5 3 1 7 2 4 6 8 DATA AUDIO 24V G G ANT Terminal option 1 2 3 MIC PRIORITY 24V L R 0dB REC MIC LINE INPUTS 3 PA 2400RC PA 4300PTT PA 2400RC AUDIO 24V...

Page 3: ...SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS 3 Deutsch Seite 4 English Page 12 Fran ais Page 20 Italiano Pagina 28 Nederlands Pagina 36 Espa ol P gina 44 Polski Strona 52 Dansk...

Page 4: ...WER Betrieb 13Ein Ausschalter POWER 14nur PA 2420Z Zonenwahltasten Z1 Z20 Zonen 1 20 ALL alle Zonen dieser Tastenreihe Nach erneutem Dr cken 2 s lang gilt wieder die vorherige Auswahl 15Anzeige des Au...

Page 5: ...weil das Kabel sehr lang ist 45RJ 45 Buchse LINK zum Anschluss eines weiteren PA 2400RC 46RJ 45 Buchse OUTPUT f r die Verbindung mit der Buchse PA 2400RC 34 des Ver st rkers oder der Buchse LINK 45 ei...

Page 6: ...er f r unabh ngige Durchsagen ber die Kommandomikrofone PA 2400RC in bis zu 2 Zonen 1 Signalgong z B zur Ank ndigung einer Durchsage mit w hlbarer Gongmelodie 2 Ton 4 Ton 2 Sirenenkl nge zur Alarmieru...

Page 7: ...leis tung aller am Verst rker angeschlossenen 100 V Laut sprecher nicht 240W berschrei ten anderenfalls kann der Verst rker be sch digt werden Abb 8 HIGH IMP 10 20 100 V 100 V 100 V 100 V 100 V 100 V...

Page 8: ...dung von St rungen bei der Signal bertragung f r einen korrekten Ab schluss der Leitung sorgen Dazu bei dem letzten Ger t der Kette den 6 Schal ter TERMINATION des DIP Schalterblocks 47 in die untere...

Page 9: ...en Ist hier keine Signalquelle angeschlossen den Regler auf 0 stellen 5 Die gew nschte Gesamtlautst rke mit dem Regler MASTER 11 einstellen Die LED Kette OUTPUT LEVEL 15 zeigt den Pegel des mit dem Re...

Page 10: ...abh ngig Der Lautst rkeregler 2 f r den Eingang 2 und der Regler MASTER hat darauf keinen Einfluss Es gibt keine Klangeinstellm glichkeit Das Signal wird nicht ber den Einschleif punkt PRE OUT AMP IN...

Page 11: ...peisung 3 Signal 15V Phantomspeisung 6 3 mm Klinke T S R S Masse T Signal R Signal Kontaktbelegung der Buchsen PRE OUT und AMP IN 6 3 mm Klinke T S S Masse T Signal 10 2 Kommandomikrofon PA 2400RC Str...

Page 12: ...a signal source with line level out put for announcements of higher priority table in fig 5 in chapter 3 25Plug in screw terminals E M MESSAGE CONTROL for connection of a normally open contact to trig...

Page 13: ...to the jack LINK 45 of a different PA 2400RC 47DIP switches for the bus address and for line termination Prior to connecting the PA 2400RC to the amplifier use the switches 1 5 to set different addre...

Page 14: ...00RC in up to 2 zones 1 signal chime e g to precede an an nouncement to be made chime melody 2 tone 4 tone can be selected 2 siren sounds for acoustic alarm 1 input for a 24V emergency power supply to...

Page 15: ...V 100 V 100 V 1 OUTPUTS 100 V 100 V 100 V 30 W PA 2410Z 60 W PA 2420Z 30 W PA 2410Z 60 W PA 2420Z 240 W Connection of the 100V speakers When connecting the speakers make sure that the speakers have t...

Page 16: ...the other units the switch must remain in the upper position 4 The amplifier provides the zone paging mi crophones with supply voltage The supply voltage will be insufficient if more than 3 zone pagi...

Page 17: ...ol to 0 5 Use the control MASTER 11 to adjust the total volume as desired The LED chain OUTPUT LEVEL 15 will indi cate the level of the mixed signal that has been adjusted with the control MASTER If t...

Page 18: ...tting of the control REMOTE 33 and of the control MIC 50 on the respective zone paging microphone The volume control 2 for the input 2 and the control MASTER will not affect the gain It is not possibl...

Page 19: ...m power 6 3mm jack T S R S ground T signal R signal Pin configuration of the jacks PRE OUT and AMP IN 6 3 mm jack T S S ground T signal 10 2 Zone paging microphone PA 2400RC Power supply 24V 16 35V vi...

Page 20: ...pe 24Bornes vis PAGING IN pour brancher une source de signal avec sortie niveau ligne pour des annonces avec priorit sup rieure tableau sch ma 5 au chapitre 3 25Bornes vis E M MESSAGE CONTROL pour bra...

Page 21: ...er un autre PA 2400RC 46Prise RJ 45 OUTPUT pour la connexion avec la prise PA 2400RC 34 de l amplifi cateur ou de la prise LINK 45 d un autre PA 2400RC 47Interrupteurs DIP pour l adresse bus et la ter...

Page 22: ...niveau ligne via connexions RCA 1 canal d entr e pour signaux d annonce avec niveau ligne via bornes vis PAGING 3 microphones de table PA 4300PTT avec touche parole pouvant tre reli s acces soires 32...

Page 23: ...hes ZONE SELECTORS 14 ou via le s lecteur rotatif 16 Dans chaque cas la puissance RMS totale de tous les haut parleurs 100V reli s l ampli ficateur ne doit pas d passer 240W Sinon l amplificateur pour...

Page 24: ...ssion du signal veillez ce que le c ble de branchement soit correctement termin Sur le dernier appareil de la cha ne mettez l interrupteur 6 TERMINA TION du bloc d interrupteur DIP 47 sur la position...

Page 25: ...ce de signal n est reli e mettez le r glage sur 0 5 R glez le volume g n ral souhait avec le r glage MASTER 11 Le VU m tre OUTPUT LEVEL 15 affiche le niveau du signal de mixage r gl avec le r glage MA...

Page 26: ...ge MIC 50 sur le microphone de commande cor respondant Le r glage de volume 2 pour l entr e 2 et le r glage MASTER n ont pas d influence Il n est pas possible de r gler la tonalit Le signal n est pas...

Page 27: ...l 15V alimentation fant me Jack 6 35 T S R S masse T signal R signal Configuration des contacts des prises PRE OUT et AMP IN jack 6 35 T S S masse T signal 10 2 Microphone de commande PA 2400RC Alimen...

Page 28: ...pitolo 3 25Morsetti ad innesto vite E M MESSAGE CONTROL per il collegamento di un con tatto di lavoro per attivare un avviso p es un avviso d emergenza se stato installa to un modulo di memoria per av...

Page 29: ...46Presa RJ 45 OUTPUT per il collegamento con la presa PA 2400RC 34 dell amplifi catore o della presa LINK 45 di un altro PA 2400RC 47Dip switch per l indirizzo bus e per la ter minazione del cavo Su...

Page 30: ...e 60W integrato per avvisi indipendenti tramite i microfoni a zone PA 2400RC in un massimo di 2 zone 1 gong p es per annunciare un avviso con melodia del gong a scelta 2 toni 4 toni 2 suoni di sirene...

Page 31: ...14 oppure tramite i selettori 16 In ogni caso la somma della potenza RMS di tutti gli altoparlanti 100V collegati con l am plificatore non deve superare 240W per non danneggiare l amplificatore Fig 8...

Page 32: ...ferenze durante la tra smissione dei segnali provvedere a una corretta terminazione del collegamento Nell ultimo apparecchio della catena por tare il 6 switch TERMINATION del blocco di dip switch 47 i...

Page 33: ...BASS TREBLE 4 4 Con il regolatore TEL PAGING LEVEL 7 impostare il volume di una fonte audio collegata ai morsetti PAGING IN 24 Se non collegata nessuna fonte di segnali mettere il regolatore sullo 0...

Page 34: ...regolatore volume 2 per l ingresso e il regolatore MASTER sono senza impor tanza in questo caso Non esiste nessuna possibilit di imposta zione dei toni Il segnale non passa attraverso il punto d inse...

Page 35: ...3mm T S R S Massa T Segnale R Segnale Piedinatura delle prese PRE OUT e AMP IN jack 6 3mm T S S Massa T Segnale 10 2 Microfono a zone PA 2400RC Alimentazione 24V 16 35V tramite PA 2410Z PA 2420Z o al...

Page 36: ...rvang een gesmolten zekering uitslui tend door een zekering van hetzelfde type 24Steekschroefklemmen PAGING IN voor de aansluiting van een signaalbron met lijnniveau uitgang voor aankondigingen met ve...

Page 37: ...snoer heel erg lang is 45RJ 45 aansluiting LINK voor aansluiting van een bijkomende PA 2400RC 46RJ 45 aansluiting OUTPUT voor de verbin ding met de aansluiting PA 2400RC 34 van de versterker of met d...

Page 38: ...gingen via de commandomicrofoons PA 2400RC in maximaal 2 zones 1 signaalgong bijv voor aanduiding van een aankondiging met selecteerbare gong melodie 2 tonen 4 tonen 2 sireneklanken voor alarmering 1...

Page 39: ...alle op de versterker aangesloten 100V luidsprekers niet groter zijn dan 240W anders kan de versterker beschadigd worden figuur 8 HIGH IMP 10 20 100 V 100 V 100 V 100 V 100 V 100 V 1 OUTPUTS 100 V 100...

Page 40: ...De totale lengte van de leiding mag niet meer dan 1000m bedragen 3 Zorg voor een correcte afsluiting van de leiding om storingen bij de signaalover dracht te vermijden Hiervoor plaatst u op het laatst...

Page 41: ...er geen signaalbron is aangesloten draait u de regelaar in de stand 0 5 Stel het gewenste totale geluidsvolume in met de regelaar MASTER 11 De led ketting OUTPUT LEVEL 15 toont het niveau van het meng...

Page 42: ...gelaar MIC 50 op de betreffen de commandomicrofoon De volumerege laar 2 voor de ingang 2 en de regelaar MASTER hebben hierop geen invloed Er is geen mogelijkheid tot instellen van de klank Het signaal...

Page 43: ...15V fantoomvoeding 6 3 mm Klinke T S R S Massa T Signaal R Signaal Penconfiguratie van de stekkerbussen PRE OUT en AMP IN 6 3 mm jack T S S Massa T Signaal 10 2 Commandomicrofoon PA 2400RC Voedingsspa...

Page 44: ...Importante La carga total carga en esta salida m s la carga total de los altavoces de las salidas de zona 18 no puede superar los 240W de lo contrario el amplificador podr a sobrecargarse 23Fusible pa...

Page 45: ...suficiente corriente cuando el LED AMP POWER 55 destelle p ej porque se han conectado m s de 3 PA 2400RC o el cable es muy largo 45Toma RJ 45 LINK para conectar otro PA 2400RC 46Toma RJ 45 OUTPUT par...

Page 46: ...e conexiones RCA 1 canal de entrada para se ales de anuncio con nivel de l nea mediante terminales de tornillo PAGING Se pueden conectar 3 micr fonos de sobremesa PA 4300PTT con bot n Talk accesorio S...

Page 47: ...iente y desconecte los dem s aparatos que hay que conectar 7 1 Altavoces ADVERTENCIA Durante el funcionamiento hay peligro de contacto con un voltaje peligroso de hasta 100V en las conexiones de altav...

Page 48: ...ueden activar mensajes guardados desde el m dulo de inserci n PA 1120DMT Las se ales de los micr fonos con control de zonas se combinar n con la se al de la entrada 2 por lo tanto el control de volume...

Page 49: ...men de un anuncio de emergencia activado me diante la entrada de conmutaci n E M MESSAGE CONTROL 25 un anuncio mediante un micr fono de sobremesa PA 4300PTT con el ajuste PRIORITY ON un anuncio median...

Page 50: ...7 1 8 7 1 Amplificador adicional en el PA 2410Z Un amplificador adicional de 60W en el PA 2410Z facilita los anuncios independientes mediante el micr fono con control de zonas PA 2400RC siempre que no...

Page 51: ...phantom Jack 6 3mm T S R S Masa T Se al R Se al Configuraci n de pines de las tomas PRE OUT y AMP IN jack 6 3mm T S S Masa T Se al 10 2 Micr fono con control de zona PA 2400RC Alimentaci n 24V 16 35V...

Page 52: ...cza w systemie 1 strefowym Uwaga Ca kowite sumaryczne obci enie tego wyj cia oraz wyj strefowych 18 moc RMS nie mo e przekroczy 240W 23Bezpiecznik dla zasilania awaryjnego 24V Spalony bezpiecznik wymi...

Page 53: ...k Dodatkowy zasilacz wymagany jest w przypadku gdy zasilane ze wzmacniacza jest niewystarczaj ce wieci si w wczas dioda AMP POWER 55 np gdy pod czono wi cej ni 3 mikrofony PA 2400RC lub kabel po czeni...

Page 54: ...PA 2400RC wyposa enie do datkowe PA 2410Z dodatkowy 60W wzmacniacz do nadawania komunikat w poprzez mi krofon strefowy PA 2400RC do max 2 stref 1 sygna gongu wyzwalany tak e ze wn trznym stykiem np d...

Page 55: ...V 100 V 100 V 100 V 100 V 1 OUTPUTS 100 V 100 V 100 V 30 W PA 2410Z 60 W PA 2420Z 30 W PA 2410Z 60 W PA 2420Z 240 W Pod czanie g o nik w 100V Podczas pod czania g o nik w zwraca uwag na jednakow polar...

Page 56: ...ch odbywa si ze wzmacniacza Wzmacniacz jest w stanie zasili 3 mikrofony strefowe Dioda AMP POWER 55 na mikrofonie strefowym sygnalizuje zasilania ze wzmac niacza je eli zaczyna miga napi cie zasilaj c...

Page 57: ...a u regulowanego pokr t em MASTER Je eli zapala si dioda CLIP sygna jest przesterowany Nale y w wczas skr ci regulator MASTER lub odpowiednie regu latory kana w wej ciowych UWAGA Nigdy nie ustawia poz...

Page 58: ...2 dla wej cia 2 oraz regulatora MASTER nie ma w tym przypadku znacze nia Nie ma mo liwo ci regulacji barwy d wi ku Nie ma mo liwo ci przes ania tego sygna u na z cza PRE OUT AMP IN 26 Nie ma mo liwo c...

Page 59: ...tom 3 sygna 15V phantom gniazdo 6 3mm T S R S Masa T sygna R sygna Konfiguracja pin w gniazd PRE OUT oraz AMP IN gniazdo 6 3mm T S S Masa T sygna 10 2 Mikrofon strefowy PA 2400RC Zasilanie 24V 16 35V...

Page 60: ...epareras p ett fackmannam ssigt s tt Om enheterna slutgiltigt ska tas ur bruk ta dem till en lokal tervin ningsanl ggning f r bortskaffande som inte skadar milj n Alle rettigheder til denne brugsvejle...

Page 61: ...l mp poiste taan laitteesta tuulettimilla l koskaan peit kotelon tuuletusaukkoja l k yt laitetta ja irrota ne v litt m sti virtal hteest 1 jos laite tai verkkojohto on n kyv sti vaurioitunut 2 jos vik...

Page 62: ...PHANTOM POWER GAIN 50 10dB CHIME R M MIC SIGNAL 1 2 3 MIC PRIORITY 24V MESSAGE CONTROL E M ATT ALL CALL M6 M5 M4 M3 M2 M1 REPEAT STOP START STOP COM G BUSY P A PROTECT OUT TRANS 100V 70V 50V 25V 12 5...

Page 63: ...AL 1 2 3 MIC PRIORITY 24V M6 M5 M4 M3 M2 M1 REPEAT STOP START STOP COM G BUSY P A PROTECT OUT TRANS 13 8 3 0 CLIP OUTPUT METER ALL CALL E M P T T RM com driver 100V MASTER L P F BIAS FAULT 17V OVER HE...

Page 64: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1842 99 01 07 2017...