42
English
6.6.7 Alarm for full disk / write error
The actions to be taken in case of a full disk or write error can
be viewed and changed in the menu “Exception”: Call up the
tile menu and then, in the tile “Alarm”, click the menu item
“Exception”.
10 s
10 s
10 s
10 s
10 s
10 s
Default
Apply
Event Type
Buzzer
Switch
Alarm Out
Show Message
Send Email
Latch Time
Exception
No Space on Disk
Disk Error
Video Loss
Fig. 6-22
Alarm menu for the events specified
Menu item
Function
Switch
To enable / disable the alarm function
Buzzer
Duration of the alarm sound
Alarm Out
To route the alarm to the normally open relay
contact ALARM (12) or ALARM OUT (17), click the
symbol and then, in the window “ Local->…”,
click the activation field
. The relay contact can
be loaded with
⎓
30 V, 1 A.
Latch Time
Switching time for the relay contact
Show Message
Full disk: , write error: ,
the menu line „Video Loss“ is without any function.
Send Email
In case of an alarm, an e-mail will be sent; to make
the e-mail settings, call up the tile “Network” and
then click the menu item “Email”
Default
To reset this menu to its factory settings
Apply
To save the settings
6.6.8 PTZ control via the RS-485 interface
– NWR-1608POE, NWR-3216POE and NWR-6400 only –
Make the required settings for remote PTZ control of cameras
that can only be operated via the RS-485 interface (17): Call
up the tile menu and then, in the tile “Channel”, click the
menu item “PTZ”.
CH1
Digital
Digital
Digital
Digital
CH2
CH3
CH4
Pelco-D
Pelco-D
Pelco-P
Pelco-P
1
2
3
4
9600
9600
9600
9600
1
1
1
1
8
8
8
8
Default
Copy
Apply
Channel Signal Type
Protocol
PTZ
Baudrate
DataBit
StopBit
Parity
Address
None
None
None
None
Fig. 6-23
Menu for setting the remote control of cameras
Menu item
Function
Channel
Number of the camera channel
Signal Type
Specification of the signal type of the camera
Protocol
Selection of the control protocol of the camera
Menu item
Function
Baudrate
Selection of the data transmission rate
DataBit
Number of data bits
StopBit
Number of stop bits
Parity
Type of the parity bit:
None, Odd, Even, Mark (always 1), Space (always 0)
Address
Address of the camera (to be able to control all
cameras connected separately)
Copy
To use the settings of a camera channel for addi-
tional channels
Default
To reset this menu to its factory settings
Apply
To save the settings
The settings for protocol, baud rate, bit etc. can be found in
the specifications of the camera.
6.6.9 Managing passwords and users
Only the administrator is allowed to make all settings for the
recorder and to use all functions. To change the name or the
password of the administrator and to grant specific rights to
the other users of the recorder, call up the menu “Multi-User”.
1) Call up the tile menu and then, in the tile “System”, click
the menu item “Multi-User”.
1
admin
2
user1
user2
user3
user4
user5
user6
3
4
5
6
7
admin
Default
Apply
No.
User Name
Level
User Enable Password Enable
Enable
Enable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
User Edit
Permission
Multi-User
USER1
USER2
USER3
USER4
USER5
USER6
Default User
ADMIN
Fig. 6-24
Menu for managing passwords and users
2) To change names and passwords, click the symbol in
the corresponding line.
admin
User Edit
Enable
Disable
User Name
Password Enable
Password Strength
Password
Confirm
Unlock Pattern Enable
Show Password
Show Password
Save
Default
Cancel
Level
ADMIN
Fig. 6-25
Window for changing names and passwords
3) In the window that is displayed, make all changes (see
chapter 6.1, if required).
Tip:
If you have forgotten the password for the admin-
istrator, you can request a “super” password per e-mail
(see Fig. 7-3, button “Forgot Password”). This, however, is
only possible when an e-mail address has previously been
defined and entered in the recorder (tile “Network, menu
item “Email”). As a precaution, define a new e-mail address
that you do not use for other purposes.