5)  When setting up a single subwoofer, it is not 

important to place the subwoofer exactly in 
the middle between the stereo speakers as 
it will not be possible to precisely locate the 
very low frequencies reproduced by the sub-
woofer . However, do not place it too close 
to walls or in corners; this would distort the 
frequency response .

Prior to making connections or changing any 
existing connections, switch off the amplifier 
module and the units to be connected .

4.1 Connecting a signal source

Connect a signal source with line level (e . g . out-
put of a mixer or preamplifier) to the RCA jacks 
LINE IN (8) . When connecting a stereo  signal 
source, a mono signal is internally created . It is 
also possible to connect the jack L / LFE to an LFE 
output . In multi-channel systems for cinema ap-
plications, e . g . “5 .1”, the LFE channel is used for 
low-frequency special effects (“Low Frequency 
Effect” or “Low Frequency Enhancement”) .

Alternatively, connect the screw terminals 

HIGH LEVEL INPUT (10) to the speaker outputs 
of a power amplifier [in parallel to the speakers 
connected there] . Connect the left channel to 
the terminal pair “L”, connect the right channel 
to “R” . Observe the correct polarity: Always con-
nect the positive pole (marked core of speaker 
cable) to the red terminal .

Caution!

• 

Only connect amplifiers with a maximum out-
put voltage of 2 × 20 V (corresponding to an 
output power of 2 × 100 W at 4 Ω or 2 × 50 W 
at 8 Ω) to these terminals .

• 

When connecting the screw terminals, make 
sure that the cable ends are only stripped for 
the length required and that no bare wires 
protrude (hazard of contact and short circuit) .

4.2 Signal output

At the RCA jacks LINE OUT (9), the input signal 
is available for being routed to another amplifier 
or active speaker system . The position of the 
controls LEVEL (5), CUT OFF (6) and PHASE (7) 
has no effect on this output signal .

4.3 Power supply

Connect the mains cable provided to the 
mains jack (2) and the plug to a mains socket 
(230 V/ 50 Hz) .

5  Operation

CAUTION

Never adjust the speaker system 
to a very high volume . Permanent 
high volumes may damage your 
hearing! Your ear will get accus-
tomed to high volumes which do 
not seem to be that high after 
some time . Therefore, do not 
further increase a high volume 
after getting used to it .

Note:

 To prevent switching noise, always switch on 

the signal source connected before switching on the 
amplifier module . After use, switch off the amplifier 
module first .

1) Before switching on for the first time, set the 

LEVEL control (5) to minimum (left stop) for 
the time being . Switch on the amplifier with 
the POWER switch (1) . As long as no signal 
is applied, the module is on standby to save 
power and the LED STANDBY/POWER (4) 
shows red . As soon as a signal is applied, the 
power amplifier is switched on and the LED 
shows green .

2)  Via the existing speaker system, reproduce 

music, for example, and add the desired low 
bass part with the LEVEL control (5) . Only 
turn up the control to such an extent that the 
sound reproduced is not distorted .

3)  Use the control CUT OFF (6) to set the upper 

cut-off frequency of the subwoofer in such 
a way that it will optimally complement the 
frequency response of the other speakers .

4)  When the speakers are placed at different 

distances to the listener, phase cancellation 
may result (certain frequencies are repro-
duced at a lower volume) . To compensate 
this effect, shift the phase of the subwoofer 
signal with the control PHASE (7) .

Test the positions of the control to find 

the one offering the bass reproduction of 
the highest volume at the listening position . 
Then readjust the volume balance with the 
LEVEL control (5), if required .

5)  If there is no signal at the input for more than 

approx . 25 minutes, the amplifier module goes 
on standby: The LED STANDBY/ POWER (4) 
shows red . If the amplifier module is not in 
use for longer intervals, switch off the ampli-
fier module with the POWER switch .

Summary of Contents for 32.0790

Page 1: ...TRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS BEDIENUNGSANLEITUNG INSTRUCTION MANUAL SAM 300D Bestell Nr Order No 32 0790 Verstärker Einbaumodul für Subwoofer Amplifier Insertion Module for Subwoofers ...

Page 2: ......

Page 3: ...ren Gebrauch 5 3 Einsatzmöglichkeiten 5 4 Montage und Anschluss 5 4 1 Signalquelle anschließen 6 4 2 Signalausgang 6 4 3 Stromversorgung 6 5 Bedienung 6 6 Technische Daten 7 English 1 Operating Elements and Connections 8 2 Safety Notes 9 3 Applications 9 4 Installation and Connection 9 4 1 Connecting a signal source 10 4 2 Signal output 10 4 3 Power supply 10 5 Operation 10 6 Specifications 11 ...

Page 4: ...eck dose 230V 50Hz über das beiliegende Netzkabel 3 Halterung für die Netzsicherung Eine durchgebrannte Sicherung nur durch eine gleichen Typs ersetzen 4 LED für den Betriebszustand rot Stand by Bereitschaft grün Endstufe eingeschaltet 5 Lautstärkeregler LEVEL 6 Regler CUT OFF zum Einstellen der Grenz frequenz für den Subwoofer 7 Regler PHASE zum Einstellen der Phasenver schiebung des Ausgangssign...

Page 5: ... dient dann als tieffrequente Ergänzung bestehender Lautsprecheranlagen wenn eine überzeugende Basswiedergabe gefordert ist Das Modul verfügt über ein Tiefpassfilter mit einer einstellbaren Grenzfrequenz 40 200Hz und einen Regler zur Phasenkorrektur im Zu sammenhang mit anderen Lautsprechern Der Verstärker ist mit einem Pegelbegrenzer Limiter zum Schutz des Lautsprechers ausgestattet Die Endstufe ...

Page 6: ...angsleistung von 2 100W an 4Ω oder 2 50W an 8Ω an Achten Sie beim Anschluss der Schraubklem men darauf dass die Kabelenden nicht zu weit abisoliert sind und keine blanken Drähte herausragen Berührungs und Kurzschluss gefahr 4 2 Signalausgang An den Cinch Buchsen LINE OUT 9 steht das Eingangssignal zum Weiterleiten zu einem wei teren Verstärker oder einer Aktiv Lautsprecher box zur Verfügung Dieses...

Page 7: ...ot Bei länge ren Betriebspausen das Verstärkermodul mit dem Schalter POWER ausschalten 6 Technische Daten Ausgangsleistung an 4Ω 8Ω Sinusleistung 300W 150W Spitzenleistung 420W 210W Frequenzbereich 20 40 200Hz obere Grenzfre quenz variabel Lastimpedanz 4 8Ω Eingangsimpedanz LINE IN 22kΩ HIGH LEVEL INPUT 270Ω Eingangsempfindlichkeit LINE IN 170mV HIGH LEVEL INPUT 1V max Eingangsspannung LINE IN 7V ...

Page 8: ... to a socket 230V 50Hz via the mains cable provided 3 Support for the mains fuse Always replace a blown fuse by one of the same type 4 Status LED red standby green power amplifier switched on 5 LEVEL control 6 CUT OFF control to set the cut off frequency for the subwoofer 7 PHASE control to shift the phase of the out put signal compared to the input signal 8 Input LINE IN RCA jacks for signals wit...

Page 9: ...o complement existing speaker systems with low frequencies when a convincing bass reproduction is required The module is provided with a low pass filter with adjustable cut off frequency 40 200Hz and a control to correct the phase in combina tion with other speakers The amplifier has a limiter to protect the speaker The power amplifier is designed as a class D amplifier It is supplied with power f...

Page 10: ...ut signal 4 3 Power supply Connect the mains cable provided to the mains jack 2 and the plug to a mains socket 230V 50Hz 5 Operation CAUTION Never adjust the speaker system to a very high volume Permanent high volumes may damage your hearing Your ear will get accus tomed to high volumes which do not seem to be that high after some time Therefore do not further increase a high volume after getting ...

Page 11: ...NE IN 170mV HIGH LEVEL INPUT 1V Input voltage max LINE IN 7V HIGH LEVEL INPUT 20V THD 0 1 S N ratio 70dB Power supply 230V 50Hz Power consumption Full load 440VA No load 24VA Standby 0 5W Ambient temperature 0 40 C Dimensions W H D 188 255 90mm Weight 1 3kg Subject to technical modification All rights reserved by MONACOR INTERNATIONAL GmbH Co KG No part of this instruction manual may be reproduced...

Page 12: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1324 99 03 04 2019 ...

Reviews: