2
© 2011 OJ Electronics A/S
© 2011 OJ Electronics A/S
Checking the GFCI
Testing can only be performed while the thermostat is calling for
heat.
Adjust the setpoint until the heating symbol (
) appears. Use the
Up
button to increase the heating demand and then press the
OK
button Wait 10 seconds to allow the thermostat to adjust to the
new setpoint.
Then press the
TEST
button on the top of the thermostat.
The test is successful if the red light in the
TEST
button lights up
and
GROUND FAULT
is shown on the display. If this does not oc-
cur, check the installation/contact your electrical installer.
Press the
Standby/Reset
button to reset the GFCI.
The red light should go out and the display returns to normal ap-
pearance.
Press the
Down
button to return to the original temperature setting.
If the test fails, check the heating cable and thermostat.
If during normal operation the GFCI trips without the
TEST
button
being pressed, there could be a ground fault! To check whether it
is a ground fault or nuisance tripping, press
Standby/Reset
.
If this causes the red light to go off and stay off, it was nuisance
tripping and the system is operating correctly. If this does not oc-
cur, there is a ground fault! Contact your electrical installer.
4-Event Program
I want the temperature to be controlled automati-
cally in accordance with a program of individual
temperature settings for four separate events during
a day:
• when I wake up in the morning,
• when I am away at work,
• when I come home,
• and at night.
To do so, you must perform the following 3 steps:
Step 1: Select automatic temperature control.
1
Press the
OK
button to activate the menu.
2
Press the
Up
or
Down
buttons until the
Mode
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until the
Auto
options flashes in
the upper part of the display.
5
Press the
OK
button.
Factory setting: Auto mode
AUTO
OVERRIDE
MAN. MODE
MODE
SCHEDULE
PROGRAM
SETTINGS
EXIT
Step 2: Choosing the weekly schedule for your
program.
You have the following options:
5:2
will give you 5 days (Monday to Friday) with the same four
events (Morning, Out, Home, Night) and 2 days (Saturday and
Sunday) with the same two events (Morning and Night).
6:1
will give you 6 days (Monday to Saturday) with the same
four events (Morning, Out, Home, Night) and 1 day (Sunday)
with the same two events (Day and Night).
7:0
will give you individual settings for each day from Monday
to Sunday.
1
Press the
OK
button to activate the menu.
2
Press the
Up
or
Down
buttons until the
Schedule
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until the required program (
5:2
,
6:1
or
7:0
) flashes in the lower part of the display.
5
Press the
OK
button.
SCHEDULE
MON
FRI
TUE WED THU
Step 3: Select the time and temperature settings for
each event in the program of days selected in the
previous step.
Please note:
The following description illustrates an example in
which settings are made for the daily events in a 5:2 program.
1
Press the
Up
or
Down
buttons until the
Program
option flashes.
2
Press the
OK
button.
3
Press the
Up
or
Down
buttons until the day(s) that you wish
to program flash in the lower part of the display, e.g.
Mon Tue
Wed Thu Fri
.
4
Press the
OK
button. The symbol for the first event (e.g. morn-
ing) will now flash.
5
Press the
OK
button. The hour will flash, allowing you to set
the hour at which you want the morning period to begin.
6
Press the
Up
or
Down
buttons until the required hour is dis-
played.
7
Press the
OK
button. The minutes will flash.
8
Press the
Up
or
Down
buttons until the required minutes are
displayed.
9
Press the
OK
button. The temperature setting will now flash in
the upper part of the display.
Type UCG/UDG
English
SET TEMP
PROGRAM
MON
FRI
TUE WED THU
EXIT
Hour
Morning
At work
At home
Night
Minutes
5-day period