Mollet MSD-070 Quick Start Manual Download Page 1

1.3  Technical data

1.1  Intended use

 

74706 Osterburken

 

Ambient temperature

 

-20 °C ... +70 °C

 

Signal contact

 

change-over contact, potentialfree

 

If the pressure reaches the switching point 

SP

, the pressure detector

 

 

Capacity of the contact

 

 

4 A / 250 V AC

 

will give a signal.

 

 

Switching voltage

 

 

24 V ... 250 V AC

 

 

 

 

or  12 V ... 125 V DC

 

Füllstandtechnik GmbH

 

Bulk good temperature

 

-25 °C ... +80 °C

 

Switching point

 

40 mbar

 

= 0.04 bar = 400 mm WS

 

Overpressure safety

 

up to 0.5 bar

 

Cable connection

 

Screw M4

Operating instructions

 

Manufacturer

 

MOLLET

 

Cable entry

 

Cable gland M20x1.5

1.  Description

 

Type

 

MSD-070

 

silos and vessels.

 

The pressure detector controls as limit switch the overpressure in

1.2  Function

 

Name

 

Silo pressure detector

 

Address

 

Industriepark RIO 103

 

Flange

 

 

Aluminium

 

 

as option 

Stainless steel  1.4571 / 316 Ti

 

Weight

 

1.1 kg

 

Membrane

 

 

Stainless steel  1.4301 / 304

 

Flange socket

 

 

Steel

 

Type of protection

 

IP65

   

acc. to DIN EN 60529

 

Maintenance

 

none

1.4  Material

 

Mounting position

 

vertical,  ±  5° inclination

 

Housing

 

 

ABS (high impact plastic), grey

1.5  Dimensions

M   LLET

Füllstandtechnik

GmbH

MOLLET   D-74706 Osterburken  Tel.  +49  6291 6440-0  Fax  +49  6291 9846           Operating instructions

04/13

  ©

 by MOLLET

        MSD-BA      

01

8. 

Attention safety device!   Don´t modify anything at the device or at the switching point adjusting!

7. 

Switch off the power supply, before opening the device. (touch dangerous voltage)

5. 

Protect the signal contact from voltage peaks when inductive loads are connected.

4. 

A fuse (with max. 4A) has to be connected upstream in series to the signal contact.

6. 

The device may put into operation if it is closed, only.

3. 

Take notice of the temperature specifications at the data plate.

Safety instructions

1. 

The installation, initial operation and maintenance may be done by a qualified expert with electrical know-how only.

2. 

Comply with the local and statutory rules and regulations and/or the VDE 0100.

Read and follow these safety instructions first and take notice of the operating instructions.

 

Flange socket

1.6  Accessory (Option)

IP

SP

T

a

T

s

Contact

MOLOS

Silo pressure detector

MSD

Ø 110

Lk 90 / 4xM8

10

150

Ø 74x2

Gasket

130x105

top

M20x1,5

124

15

10

66

Ø 69

Lk 90 / 4xØ 9

Ø 110

008-0200