background image

Molift Air / www.etac.com 

1

Important

This User Manual contains important safety instructions and 
information regarding the use of the sling and accessories. 
In this manual the client is the person being lifted. 
The caregiver is the person operating the lifter.

This symbol indicates important information 
related to safety. Follow these instructions 
carefully.

Read User Manual before use!  
It is important to fully understand the con-
tent of the user manual before attempting to 
use the equipment.

Visit www.etac.com for download of documentation to ensure 
you have the latest version.

Molift Air 200/350

1

2

3

7

8

6

5

4

Hoist components:

1.  Trolley
2.  Hoist
3.  Side covers
4.  Emergency stop/ Emergency 

lowering

5.  Lifting belt
6.  Quick release pin
7.  Hand control
8.  Sling bar

About Molift Air

Molift AIR is a strong and smooth ceiling lift that enables patients 
and residences to be transferred in a comfortable and safe way. 
Suitable for sitting and lateral transfers as well as standing and 
gait training situations together with the comprehensive acces-
sory program from Molift.
Molift AIR is a very light motor which in combination with the 
quick release coupling system gives an easy handling when 
mounting and servicing

General

Declaration of conformity:

The Molift Air and related accessories described 
in this operator manual are CE marked in 
accordance with EU Council Directive 93/42/EEC 
concerning medical devices, class 1, and has been 
tested and approved by a third party according to 
standards IEC 60601-1, IEC 60601-1-2 and NS-EN 
ISO 10535:2006.

Conditions for Use

Lift and transfer of a client will always pose a certain risk and 
only trained personnel are allowed to use the equipment and 
accessories covered by this user manual. The rail system must 
be installed by certified personnel in accordance with applicable 
installation instructions.

Modifications and use of components made by other manufacturers.

We recommend only using Molift components and spare parts. 
Declaration of conformity is not valid and Etac is not responsible 
for warranty if any modifications are made to the product. Etac 
shall not be liable for faults or accidents that can occur when 
using components made by other manufacturers.

The lifter is not intended to be operated by the client being lifted. 
If a hoist is to be used by a client living on their own, then some 
form of communication device shall be installed in the area of use 
of the hoist so that in the event of an emergency the client is able 
to summon assistance. This may, for example, be the fitting of an 
alarm system or the supply of a conveniently placed telephone, 
etc.

Only certified personnel are allowed to open 
hoist or accessories to perform service or 
repair. Risk of injury from rotating parts and 
electric shock.

Warranty: 

2-year warranty against defects in 

workmanship and materials of our products. 1 
year warranty for battery.
For Terms and conditions, see www.etac.com

Summary of Contents for Air 200

Page 1: ...Molift Air 200 350 User manual BM16199 Rev B 2018 01 10 ...

Page 2: ...Council Directive 93 42 EEC concerning medical devices class 1 and has been tested and approved by a third party according to standards IEC 60601 1 IEC 60601 1 2 and NS EN ISO 10535 2006 Conditions for Use Lift and transfer of a client will always pose a certain risk and only trained personnel are allowed to use the equipment and accessories covered by this user manual The rail system must be inst...

Page 3: ...Load SWL Molift AIR 200 205 kg 450 lbs Molift AIR 350 350kg 771 lbs Weight of unit Chassis incl battery Excl sling bar 8 56 kg 18 87 lbs 4 point Medium Sling bar 2 2 kg 4 8 lbs Battery Art 2920204 25 6 V LiFePO4 2 4 Ah Art 2920007 12 V SLA 2 9 Ah Battery charger IRC applies for Molift Air 350 only Charger for handcontrol Mascot type 3743 Art no 2540100 100 240 V AC 50 60 Hz max 0 5A Output 0 9A IR...

Page 4: ...s checklist to verify that the hoist is properly installed and can operate correctly and safely before use End stops on rail are installed after mounting of trolley as described in BM4401 Make sure that the hoist is properly fastened to the rail and that the lift does not have any loose parts Perform one lift with load 60 80 kg Make sure battery is fully charged How to use Molift Air General Safet...

Page 5: ...d to start lowering Hold until client is lowered and can be released from sling bar Only for emergency use when hand control does not work Manual Emergency lowering Allen key or bit for power drill can be found inside the lifter Remove cover to locate Push down and press cover outwards with a flat screwdriver or coin in the two slots to open cover Turn the Brake Release handle down Only for Air 35...

Page 6: ...t class 2 Contact Etac your local dealer or see etac com for a recommendation of an approved service partner The electrical system has a power save function which will turn off the electrical system five minutes after last operation All indicators will turn off The system is activated when pushing one of the operating but tons on the hand control Service indicator Mode No light No service needed Y...

Page 7: ...10119 Charger 3844 DC DC Part of Molift Air IRC Art no 2640101 Transfer Plan the lifting operation in advance to ensure that it is as safe and smooth as possible Remember to work ergonomically Assess the risks and take notes The assistant is responsible for the safety of the user Molift Air can be used with both 2 point and 4 point sling bar for different types of transfers sitting recumbent or am...

Page 8: ...inum 550 mm Art no 2530212 4 point X Large aluminum 650 mm Art no 2530213 8 point sling bar for fabric stretcher steel Art no 2140003 Scale Molift Scale Set without Sling bar Art no 1840000 Can be combined with all Molift Air compatible sling bars Scale is approved Class III The scale can also calculate BMI Body Mass Index with a single touch Read the manual that comes with the weight scale prior ...

Page 9: ...ccording to Periodic Inspection Report for Molift Air 200 and 350 See www etac com Periodic Inspection shall be performed at least once a year or more frequently if required by local requirements The inspection must be performed by service personnel authorized by Etac Contact Etac at molift etac com for training and authorization or recommendation of an approved service partner When performing a p...

Reviews: