APPLICATION SPECIFICATION
REVISION:
ECR/ECN INFORMATION: TITLE:
Installation Instructions PID-00231
MIIM Category 6A Patch Panel
SHEET No.
A
EC No:
MTS2012-0032
1
of
4
DATE:
2013 / 01 / 21
DOCUMENT NUMBER:
CREATED / REVISED BY:
CHECKED BY:
APPROVED BY:
AS-18700-059
BJ Mahendra
CG Raghavan
Samuel Huber
TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC
INSTALLATION INSTRUCTIONS: PID-00231 PANEL
PARTS LIST
Panel with Integrated Cable Manager
Hardware Kit
Rear Housing Assembly
Stuffer Caps
Labels
Instruction Sheet
GENERAL REQUIREMENTS
The following tools are required for installation of
the panel:
110 termination tool set on low impact
Flush cut pliers
Cable stripping tool
Phillips screwdriver
ASSEMBLY INSTRUCTIONS
1. Panel Preparation
1a. Remove cable management tray from panel.
1b. For each cable, slide rear housing on cable
in the proper direction.