background image

HDAC 0.64 User Manual                                       

11

A. Un-mate procedure

To un-mate the connectors, push connector together to unload the latch system. 

Than depress the latch with your thumb (step 1). Continue to depress the latch, and gently pull apart 

connector assemblies (step2).

Section 5: Service Instructions

Step 1

Step 2

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Summary of Contents for HDAC .64 Series

Page 1: ...HDAC 64 User Manual Connector Assembly Reference Manual REV 1 May 9 2006 Downloaded from Elcodis com electronic components distributor...

Page 2: ...Table of Contents Section 1 Product Introduction Section 2 Product Summary Section 3 Connector Assembly Section 4 Connector Mating Section 5 Service Instructions Downloaded from Elcodis com electronic...

Page 3: ...HDAC 0 64 User Manual 3 Product Introduction HDAC 0 64 Product Line Downloaded from Elcodis com electronic components distributor...

Page 4: ...product ordering information please contact your Molex Inside Sales Representative at 800 786 6539 For electronic copies and future updates of this document and the Connector Reference Manual refer to...

Page 5: ...ser Manual 5 Section 2 Product Summary HDAC 0 64 Receptacle Connector Assembly HDAC 0 64 Blade Connector Assembly Housing TPA A Connector Assemblies Downloaded from Elcodis com electronic components d...

Page 6: ...inal PN 34083 3001 Base Material 9 Copper Alloy Plating Options 9 Tin Gold Wire Sizes 9 16 18 20 22 AWG TYCO Blade Terminal Base Material 9 Copper Alloy Plating Options 9 Tin Gold Wire Sizes 9 16 18 2...

Page 7: ...in As Shipped Connector Position TPA s shown in as shipped condition pre lock The TPA must remain in the pre lock position until all circuits are loaded Section 3 Connector Assembly Downloaded from El...

Page 8: ...al insulation crimp and insert through appropriate circuit opening If resistance is encountered retract the terminal and adjust the angle of insertion Continue inserting the terminal until it stops an...

Page 9: ...lled the TPA can be seated into its final lock position by applying an even force to the TPA surface until it comes to a stop with an audible click Section 3 Connector Assembly Push uniformly on TPA m...

Page 10: ...ector to blade connector Begin mating procedure by sliding the receptacle connector assembly and blade connector assembly together press firmly until you hear an audible click Keying Features Section...

Page 11: ...onnector together to unload the latch system Than depress the latch with your thumb step 1 Continue to depress the latch and gently pull apart connector assemblies step2 Section 5 Service Instructions...

Page 12: ...ry point Step 2 Using the housing as a pivot point gently push out on the TPA until it is removed from the connector housing If TPA is damaged Do Not Reuse Excessive force may damage the TPA Section 5...

Page 13: ...screwdriver into the two small extraction holes Step 2 Push on opposite sides of the TPA latch until it is removed from the connector housing If TPA is damaged Do Not Reuse Excessive force may damage...

Page 14: ...n the wire to release the terminal If the terminal resists the service tool may not be fully engaged Gently push the service tool further into the terminal lock finger to ensure that it has fully dise...