method will be labeled with the name of the data file it was created
from. However, if a single export file is desired that contains
information for multiple data files, select
Use user-defined name
in
the respective section. In this instance, all exported information will be
combined into one file labeled with the desired user-defined name.
When the file is open, the individual data file names which the
information was exported from are used as the header for each data set
within the export file.
Image Display
Use the
Image Display
dialog, opened from the
Analysis
process
page, to view images saved in data files when
Save Images
was
enabled during a
Read with TF
step. This option stores a total of 100
images per experiment; the number of images per dispense is
user-defined. The default is set to one image before and nineteen
images after the fluid addition is initiated. Saved *
.tif
files can be
played back in sequence, frame-by-frame or as a video.
Image Display
is useful for diagnosing problems. For example, if cells
are blown off during a fluid dispense, you will see dark holes in the
middle of the cell layer after the fluid addition. If the entire well
decreases in relative light units, it is likely that extracellular dye has
been diluted.
Notes
In protocol files, open the
Protocol Notes
dialog where you can enter
comments that you want kept with all data files generated with the
protocol. The dialog contains a simple text editor for you to format your
comments.
In data files the same dialog shows the comments that were added in
the protocol file, now in read-only format, so they cannot be edited.
Summary of Contents for FLIPR Tetra
Page 1: ...FLIPR Tetra High Throughput Cellular Screening System User Guide 0112 0109 H December 2011...
Page 12: ...Contents 12 0112 0109 H...
Page 16: ...System Overview 16 0112 0109 H...
Page 40: ...System Hardware Features 40 0112 0109 H...
Page 148: ...Exchanging Hardware 148 0112 0109 H...
Page 156: ...Calibration and Signal Test 156 0112 0109 H...
Page 196: ...Running an Experiment 196 0112 0109 H...
Page 232: ...Robotic Integration 232 0112 0109 H The following drawings illustrate these requirements...
Page 282: ...Data Processing Algorithms 282 0112 0109 H...
Page 294: ...Consumables and Accessories 294 0112 0109 H...
Page 298: ...Using AquaMax Sterilant 298 0112 0109 H...
Page 302: ...Electromagnetic Compatibility EMC 302 0112 0109 H...