3.16.6 E-Multi Injection Unit Installation onto the Molding
Machine
WARNING - CRUSH HAZARD
A crushing hazard exists between the adapter plate and the mounting
surface of the mold.
This procedure begins with the E-Multi injection unit in a vertical position,
attached to a lifting machine.
1. Remove the support legs of the E-Multi injection unit.
2. Clean the molding machine and mold where the E-Multi injection unit will
be mounted. Any plastic residue on the manifold inlet must be removed to
ensure proper nozzle contact.
3.
Raise the E-Multi injection unit off the floor using the lifting machine.
4. Clean the adapter plate mating surfaces.
5. Lift the E-Multi injection unit into place above the manifold inlet.
6. Install screws and torque in a crosswise pattern. See “Screw Torque
7. Ensure the E-Multi injection unit is securely installed on the molding
machine.
8. Remove the lifting equipment from the E-Multi injection unit.
5. Continue to slowly raise the E-Multi injection unit until it is in a vertical
orientation, keeping the lifting machine centered over the unit.
3-30
E-Multi User Manual
SAFETY
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.