MOKO TECHNOLOGY LTD.
MKL62ST-DT User Manual
www.mokosmart.com
@Copyright 2019 MOKO All Rights Reserved
Examples:C2 0B 14 1A 00 00 00
C2 0B: The converted integer is 3010, and the actual temperature is 30.1 degree
14 1A: The converted integer is 6676, and the actual humidity is 66.76%RH
6.2.2 LED Indicator
6.2.3 Uplink packet format
Bytes
Type
Data Type Description
1-2
Temperature Int
The data format is Little-endian, and data type is signed int.
After the data is converted, the actual value needs to be
divided by 100.
3-4
Humidity
Uint
The data format is Little-endian, and data type is unsigned
int. After the data is converted, the actual value needs to be
divided by 100.
5-7
Battery Level Uint
Reserved for battery information
Items
Indicator
Power on
Solid blue
Communication light
Solid green
Transmitter data
Green LED blink
Receive data
Blue LED blink