MoistAir MA 0950 Owner'S Manual Download Page 2

Safety Signal Words

DANGER:

means if the safety information is

not followed someone 

will

be seriously

injured or killed.

WARNING:

means if the safety information is

not followed someone 

could

be seriously

injured or killed.

CAUTION:

means if the safety information is

not followed someone 

may 

be injured.

1. To reduce the risk of fire or shock hazard,

plug humidifier directly into a 120V, A.C.
electrical outlet. Do not use extension
cords.

2.  Keep the electric cord out of traffic areas.

To reduce the risk of fire hazard, never put
the electric cord under rugs, near heat
registers, radiators, stoves or heaters.

3.  Always unplug the humidifier before mov-

ing it, removing the fan assembly section,
before cleaning, or whenever the humidifi-
er is not in service.

4.  Keep the humidifier clean.
5. Do not put foreign objects inside the

humidifier.

6.  Never use your humidifier while any part is

missing or damaged in any manner.

7.  To reduce the risk of electrical hazard or

damage to humidifier, do not tilt, jolt or tip
humidifier over while unit is running.

8. To reduce the risk of damage to humidifi-

er, unplug humidifier when water bottles
are empty or when the humidifier is not in
use.

9. To reduce the risk of accidental electrical

shock, do not touch the cord or controls
with wet hands.

10. Note the warning label shown below.

WARNING: To reduce the risk of fire, electric
shock, or injury always unplug before filling,
servicing or cleaning.

GENERAL SAFETY INSTRUCTIONS

2

Limited Warranty

All products covered by this Owner’s Manual are warranted against defects in work-
manship and materials for one year from the date of sale except for motors, which
are warranted for two years. This warranty does not apply to damage from accident,
misuse or alteration nor where the connected voltage is more than 5% above the
nameplate voltage, nor to the equipment improperly installed or wired 
or maintained in violation of this Owner’s Manual. No other written or oral 
warranty applies. No employee, agent, dealer or other person is authorized to give
any warranties on behalf of Emerson.
The customer shall be responsible for all costs incurred in the removal or 
reinstallation and shipping of the product for repairs. Within the limitations of 
this warranty, inoperative units should be returned, with a copy of the sales receipt,
freight prepaid to a local repair service center and we will repair or replace, at our
option, at no charge to you with return freight paid by Emerson. It is agreed that such
repair or replacement is the exclusive remedy available from Emerson and that

Emerson Is Not Responsible For Damages Of Any Kind, Including Incidental
And Consequential Damage. 

Some states or provinces do not allow the exclusion

or limitation of incidental or consequential damages, so the above exclusion or lim-
itation may not apply to you.
The warranty gives you specific legal rights, and you may also have other rights
which vary from state to state or province to province.

Sales receipt required as proof of purchase for warranty claims.

SP6549 Manual 71235  7/12/05  3:17 PM  Page 2

Summary of Contents for MA 0950

Page 1: ...Canada CAUTION READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION SAVE THIS OWNER S MANUAL FOR FUTURE REFERENCE Model No MA 0950 0 MA 0950 Evaporative Console Humidifier Owner s Manual SP6549 Manual 71235 7 12 05 3 17 PM Page 1 ...

Page 2: ...L SAFETY INSTRUCTIONS 2 Limited Warranty All products covered by this Owner s Manual are warranted against defects in work manship and materials for one year from the date of sale except for motors which are warranted for two years This warranty does not apply to damage from accident misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipmen...

Page 3: ...s Fill Light Yes Auto Humidistat Yes Auto Shut Off Yes Controls Rotary CUL Listed Yes Volts 120 A C Hertz 60 Amps 0 80 Watts 80 Know Your Humidifier 3 Based on an area with average insulation and an 8 foot ceiling height Bottle Handle Speed Control Bottle Base Filter Replacement No MAF 1 Fan Assembly Humidity Control Housing Assembly SP6549 Manual 71235 7 12 05 3 17 PM Page 3 ...

Page 4: ...sed in the form of vapor No water droplets will enter the home All evaporation into the air takes place in the humidifier which means that the residue left by evaporat ing water is not passed into the home but remains in the filter This natural process of evaporation helps eliminate the chance of white dust in the humidified output air CAUTION Use only liquid EPA Registered Bacteriostat available ...

Page 5: ...n affect the effi ciencies of the controls Unit should not be placed where warm air from a hot air register blows directly on unit Step 2 The humidifier should be positioned with the back cord exit side and left side at least 2 inches away from the wall Air needs to enter through all of the louvers in the housing assembly in order for the humidifier to operate at peak efficiency Locate nearest 120...

Page 6: ... whole house humidifier will hold 1 9 gallons of water The water bottle is designed with a Side Fill Cap Remove the Cap on the side of the water bottle by twisting counter clockwise Place the opening of the water bottle under a water faucet and fill If desired add liquid bacteriostat to help control the build up of bacteria and algae Do not use solid water treatments Solid debris could make the lo...

Page 7: ...turned off or unplugged Humidity Control Adjust the amount of humidity depending on your needs The humidifier will turn on and off as required to maintain level of humidity selected A medium setting half way between the controls rotation is recommended but there are times when low or high amount of humidity may be preferred For con stant operation of humidifier rotating the control all the way clo...

Page 8: ...rements for that setting or it is adjusting to the home con ditions The table below shows recom mended indoor humidity levels The figure below shows approximate relative humidi ty percentages which correspond to the various settings of the Humidity Control Using Your Humidifier Operating Tips for Best Performance 1 Position the humidifier next to an inside wall at least 2 inches from the wall and ...

Page 9: ...ilters we recommend moving the humidifier to an area where floor coverings are not susceptible to water damage i e kitchen or bath areas 2 Remove the water bottle and set aside Be sure not to bump or damage the lower spring valve 3 Grasp the housing assembly and lift straight up and away from the base and set aside The filter is now accessible 4 Take note of the filter position Remove the filter a...

Page 10: ...g assembly to the top of the base Return the water bot tle to the right of the housing assem bly and reposition the humidifier to its operating position 7 The humidifier is now ready to be filled for operation Replacement and Care of Filters continued 10 Base Position start and finish of coiled filter at center of base Align housing assembly bottom with top of base and reposition securely Return b...

Page 11: ...able at your local retail store Step 1 To make cleaning easier the humidifier base should be empty and completely dried out To accomplish this use the following method a Allow the humidifier to run until the amber Refill light illuminates and the automatic shutoff has stopped the humidifier fan b Unplug humidifier WARNING If humidifier is not un plugged fan could start after housing is removed Ste...

Page 12: ...to the base Coil the filter and position it between the uprights in the bottom of the base The start and finish of the coil should be captured in the centre of the base see diagram and the filter should be resting on the floor of the base 2 Return the housing assembly to the top of the base Return the water bottle to the right of the housing assembly and reposition the humidifier to its operating ...

Page 13: ... speed control clock wise Raise humidistat setting Turn humidity control counter clockwise until the fan turns off Allow up to 24 hours of run time for unit to adjust Designed to satisfy an area up to 2000 sq ft Free float from obstruction A small amount of water remains in the base after the Refill Light comes on Check Side Fill Cap and lower spring assembly Check for leak in water bottle Ensure ...

Page 14: ...Repair Parts Parts List for MoistAir Humidifier Model No MA 0950 0 14 SP6549 Manual 71235 7 12 05 3 17 PM Page 14 ...

Page 15: ...r is done by a qualified service technician 15 Key No Part No Description 1 830488 Housing Upper 2 830782 1 Assembly Control 3 830494 1 Knob 4 829821 Blade Fan 5 830778 Motor 6 823728 Switch Micro 7 830489 1 Housing Lower 8 MAF 1 Filter 9 829815 Screw Pan Hd Ty AB 6 x 1 2 SS 10 830496 1 Support Float 11 829816 Float 12 830484 1 Base 13 829808 Foot Rubber 14 830537 1 Bottle Includes Key 15 15 82469...

Page 16: ...11 04 FOR TECHNICAL HELP CALL 800 654 3545 FROM USA OR 888 744 4687 FROM CANADA Please have complete model number Emerson Tool Company For more information about MoistAir humidifiers visit our website at www moistair com SP6549 Manual 71235 7 12 05 3 17 PM Page 16 ...