MOHAWK MODEL ML-220
55
New Slab Recommendations:
The information contained in this appendage supercedes any other information given in the accompanied manual. This
information is presented for design recommendations for a new concrete slab in the event that the pre-existing floor does not meet
minimum requirements of the applicable lift type. Please read all instructions below carefully before producing new slab.
Basic Concrete Requirements:
Minimum Tensile Strength of Concrete:
4,000 P.S.I.
Minimum Aging of New Concrete Slab:
28 days (cure time)
Minimum Thickness of Concrete Slab:
See New Slab Table & Figure Attached
Minimum Width and Length of Slab:
See New Slab Table & Figure Attached
All properties of the new concrete slab are mandatory and must conform to the above stated properties before installation
of the lift is deemed acceptable. The new slab must be totally surrounded by an existing concrete floor. Certified strength
documentation should be obtained from the firm who supplies the concrete mixture at the time of the pour.
7KHVODEDERYHLVGHVLJQHGDV³VWDQGDORQH´DQGGRHVQRWWDNHLQWRDFFRXQWWKHFRQWULEXWLRQRIVWUHQJWKIURPVXUURXQGLQJ
concrete. It may be desirable to reinforce the new slab to the pre-existing surrounding floor. Care should be taken to locate these
specific reinforcement bars away from any anchor positions of the specific lift.
This new slab design does not account for second floor installations or installations in a ground floor with a basement
beneath. For this case, the lift should not be installed without written authorization from the building architect.
All
¾
inch diameter anchors must be a minimum of 6 inches away from any expansion seams, control joints or other
inconsistencies in the concrete. All 1 inch diameter anchors must be a minimum of 7
½
inches away from any expansion seams,
control joints or other inconsistencies in the concrete. Refer to anchor manufacturer specifications for specific information
concerning edge distances and bolt to bolt distance requirements.
NEVER, NEVER, hand mix your own concrete.
Rev: 6/7/06
File: New-Slab.doc
Summary of Contents for ML-220
Page 26: ...MOHAWK MODEL ML 220 20 Figure 1 ...
Page 27: ...MOHAWK MODEL ML 220 21 Figure 2 ...
Page 28: ...MOHAWK MODEL ML 220 22 Figure 3 ...
Page 29: ...MOHAWK MODEL ML 220 23 Figure 4a ...
Page 30: ...MOHAWK MODEL ML 220 24 Figure 4b ...
Page 31: ...MOHAWK MODEL ML 220 25 Figure 5 ...
Page 32: ...MOHAWK MODEL ML 220 26 Figure 6 ...
Page 33: ...MOHAWK MODEL ML 220 27 Figure 6A ...
Page 34: ...MOHAWK MODEL ML 220 28 Figure 7 ...
Page 35: ...MOHAWK MODEL ML 220 29 Figure 8 ...
Page 36: ...MOHAWK MODEL ML 220 30 Figure 9 ...
Page 37: ...MOHAWK MODEL ML 220 31 Figure 10 ...
Page 38: ...MOHAWK MODEL ML 220 32 Figure 11 ...
Page 39: ...MOHAWK MODEL ML 220 33 Figure 12 ...
Page 40: ...MOHAWK MODEL ML 220 34 Figure 13 ...
Page 41: ...MOHAWK MODEL ML 220 35 Figure 14 ...
Page 43: ...MOHAWK MODEL ML 220 37 ...
Page 44: ...MOHAWK MODEL ML 220 38 ...
Page 45: ...MOHAWK MODEL ML 220 39 ...
Page 46: ...MOHAWK MODEL ML 220 40 ...
Page 47: ...MOHAWK MODEL ML 220 41 ...
Page 48: ...MOHAWK MODEL ML 220 42 ...
Page 49: ...MOHAWK MODEL ML 220 43 ...
Page 50: ...MOHAWK MODEL ML 220 44 ...
Page 51: ...MOHAWK MODEL ML 220 45 ...
Page 52: ...MOHAWK MODEL ML 220 46 ...
Page 53: ...MOHAWK MODEL ML 220 47 ...
Page 54: ...MOHAWK MODEL ML 220 48 ...
Page 55: ...MOHAWK MODEL ML 220 49 ...
Page 56: ...MOHAWK MODEL ML 220 50 ...
Page 57: ...MOHAWK MODEL ML 220 51 ...
Page 58: ...MOHAWK MODEL ML 220 52 ...
Page 63: ...MOHAWK MODEL ML 220 57 ...
Page 64: ...MOHAWK MODEL ML 220 58 ...
Page 65: ...MOHAWK MODEL ML 220 59 ...
Page 66: ...MOHAWK MODEL ML 220 60 ...
Page 67: ...MOHAWK MODEL ML 220 61 ...
Page 68: ...MOHAWK MODEL ML 220 62 ...