background image

PICTURE 1 

Terminal Connections

INSTALLATION DATA SHEET

LED201/200 Series

Carefully  twist  lens  firmly  one  turn  clockwise  to  remove  from  base.  Remove  3  x  No:4  screws 

from  LED  mounting  plate  that  fix  plate  to  internal  lugs  in  the  base.  Fix  base  to  the  required 

surface,  utilising  rubber  gasket,  with  2  x  M4  screws  (not  supplied).  Insert  power  cable  through 

aperture in base & connect to the 4 way terminal on the PCB. ‘see picture 1’. Position the base of the 

LED array over the internal base lugs & fix in place with 3 x No:4 screws.

LED401/400 Series

Connection to this type of unit is either into the three way barrier strip situated in the base of the 

unit (standard connection) or via the M20 side conduit entry. If M20 is preferred method then two 

wires in the barrier strip in the base need to be unscrewed and freed from the barrier strip. Un-screw 

3 x No:4 screws that retain the base plate & carefully remove, threading the wires through the aperture. 

Un-screw the same two wires from the internal terminal block. Carefully drill out the M20 entry & 

using the appropriate cable gland, insert power cable into unit connecting to the internal terminal block. 

Screw base plate back into position. Fix base to the required surface using the supplied gasket with 

3 x M6 Hex set screws (not supplied).

Alarm Stages (Modes of Operation)

These are selected by a two way dip switch on the lens side of the PCB at installation. 

The operational mode is factory pre-set to FLASH.

Replace  lens  onto  base  ensuring  that  the  base  spigot  ‘O’  ring  is  in  place.  Twist  lens  one  turn 

anti-clockwise to lock & check that the ‘O’ ring is positioned correctly & not caught or snagged.

General Installation Notes

•  Installation must be carried out in accordance with the latest codes of practice by 

  a qualified electrician.

•  Ensure power is disconnected prior to installation or maintenance to avoid electrical shock.

•  Environmental exposure conditions during installation should be dry, not moist or wet.

•  The lens of the unit is polycarbonate plastic. Do not clean with petroleum based cleaners.

•  To maintain the IP65 weatherproof rating the beacon must be mounted with 

  the lens above the base.

•  Avoid mounting the beacon where it will be subject to excessive vibration.

LED201/200 Series

LED401/400 Series

ON

1              2

STEADY

1 BAR ROTATING

FLASH

2 BAR ROTATING

SWITCH

POSITION

ON

ON

ON

1              2

1              2

1              2

+V (L) Power In Ov (N)