Moffat TV337 Owners And Installation Manual Download Page 9

9

REMOVE EXHAUST ADAPTOR*

If exhausting/venting using the 3¼

x 10

rectangular

duct

Remove the exhaust adaptor from the inside of the
hood. Set it aside along with its mounting screws. 

x 10

rectangular
exhaust
adaptor
and screws

REMOVE FILTER

Remove the shipping tape holding the 

metal grease

filter

in place. Pull down on the center of the front

edge of the filter. The filter will then slip out of the
retaining tabs on the back.

REMOVE WIRING COVER

Remove the 

wiring cover

from inside the hood. 

Set the cover and its mounting screw aside. 

Wiring
cover

REMOVE WIRING KNOCKOUT

Remove either the top or the back wiring knockout as
needed and install an approved 

strain relief clamp. 

Strain relief
clamp

2

3

4

5

Metal grease filter

Installation Instructions

Back knockout

Top knockout

Strain relief
clamp

* 1” = 2.5 cm

FOR 3¼

X 10

RECTANGULAR

DUCTED DISCHARGE
INSTALLATIONS ONLY:*

Attach

exhaust adaptor/damper

over the appropriate

knockout opening (for vertical or horizontal,
depending on installation) with two exhaust adaptor
screws. Make sure damper 

pivot

is nearest to 

top/back

edge

of hood. Remove 

tape

from damper flap.

Up to 1

side-to-

side adjustment

Tape

Top/back edge

Exhaust adaptor/damper
(vertical discharge position)

Pivot
(depending on
installation)

6

NOTE:

The exhaust adaptor/damper can be installed

up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-
center installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.

Exhaust adaptor/damper
(horizontal discharge position)

Summary of Contents for TV337

Page 1: ...Hood Light 4 Hood Surfaces 4 Controls 3 Installation Instructions 5 13 Consumer Support Consumer Support Back Cover Warranty 14 TV337 Vent options only Owner s Manual and Installation Instructions Wr...

Page 2: ...her and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based...

Page 3: ...Instructions 3 Using the hood controls Throughout this manual features and appearance may vary from your model FAN Control Turn to HI MED or LO as needed Continuous use of the fan system while cooking...

Page 4: ...ver into the top opening Gently push the cover up and press the sides to fit the side prongs into the side openings Release and the cover will lock in position Hood Light The charcoal filter cannot be...

Page 5: ...with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure dampers swing freely and nothing is blocking the ducts Elbows transitions wall and roofc...

Page 6: ...IVALENT NUMBER PIECES LENGTH x USED TOTAL 6 Round 24 Ft x Ft wall cap 18 ft w o with damper x Ft damper 6 Round 33 Ft x Ft roof cap 6 Round 2 Ft x Ft to 3 x 10 rect transition 6 Round 4 Ft x Ft to 3 x...

Page 7: ...mer repair or replacement must be made by arrangement between customer and installer DAMAGE SHIPMENT INSTALLATION PARTS INCLUDED MOUNTING SPACE NOTES This range hood is for installation over ranges or...

Page 8: ...CHOOSE VENT OPTION Determine the vent option that your installation will require and that is available for your model from the below choices 1 IMPORTANT If the hood is to be installed in a recirculati...

Page 9: ...Strain relief clamp 2 3 4 5 Metal grease filter Installation Instructions Back knockout Top knockout Strain relief clamp 1 2 5 cm FOR 3 X 10 RECTANGULAR DUCTED DISCHARGE INSTALLATIONS ONLY Attach exha...

Page 10: ...Wood shims recessed bottom cabinets only shims must be a minimum of 3 8 thick and cut to fit the width of the inner recessed cabinet bottom Vertical duct access hole 95 8 13 8 1 7 3 A Outside top exh...

Page 11: ...d the front of the cabinet so you can move the duct freely when installing the hood It may also ease installation by cutting the hole 10 instead of 10 10 1 Ft 0 3 m 1 2 5 cm SCREW IN PARTWAY Drive a m...

Page 12: ...ete the electrical wiring according to National Electrical Code and local codes NOTE This hood must be permanently grounded Connect house wiring 120 VAC to hood wiring 18 INSTALL LIGHT BULB NOTE A lig...

Page 13: ...e Reinstall and adjust as needed The fan does not work but the lights do Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accident...

Page 14: ...within Canada If the product is located in an area where service by a Mabe Authorized Servicer is not available you may be responsible for a trip charge or you may be required to bring the product to...

Page 15: ...www moffatappliances ca Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line...

Reviews: