Appendix 1 - Proofer Door Reversal
16
Reversing the Proofer Door
(P8 / P12 Only)
NOTE:
Refit all screw fasteners using a low-mid strength
thread locking adhesive unless otherwise stated.
Door reversal should only be carried out by a
suitably competent person.
1. Whilst supporting door remove bottom hinge body
(two screws) and remove door.
2. Remove top hinge body (two screws).
3. Remove four cover screws covering alternate hinge
holes. Refit cover screws on opposite side.
4. Remove the LH side panel (four screws).
When Changing to RH Hinged Door.
1. Remove the LH magnet plate cover screws and clips
from inside LH wall (Do not fit cover screws to old
magnet position).
2. Transfer door magnet plate to the opposite side.
When Changing to LH Hinged Door.
1. Remove magnet plate and transfer to the opposite
side.
Important: Redundant plate holes in LH side
wall must be filled to stop steam ingress into
the wall cavity.
2. Fit bottom hinge body to top on opposite side, centre
hinge on slots.
3. Whilst holding door in place fit remaining hinge body
to bottom, securing door in position.
4. Ensure door seal is removed and re-fitted with the
join in the seal at bottom.
5. Refit the LH side panel.