4
Electrical supply connection point is located at the rear of the appliance, approximately 130mm from
the right hand side and 31mm from the rear of the appliance. 85mm from bench height on bench
models and 740mm from the floor on leg stand and cabinet base models. (Refer to the ‘Dimensions’
section).
When connecting a this electric appliance to the mains supply, ensure that the following is carried
out:-
An isolating switch is fitted within 2m of the appliance, but not on the appliance and in such a
position that the user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS 3191
part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around the wiring entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
For the Refrigeration Cabinet Specifications, refer to the Refrigeration Cabinet Installation and
Operation Manual supplied with the appliance.
Model
Power Supply
Total Power
Input
Amps
Voltage
Type
Frequency
L1
L2
L3
E512D
230-240 Vac
1 P+N+E
50 / 60 Hz
4.8 kW
20.0
---
---
E512C
230-240 Vac
1 P+N+E
50 / 60 Hz
3.4 kW
14.2
---
---
E514D
400-415 Vac
2 P+N+E
50 / 60 Hz
9.6 kW
20.0
20.0
---
E514C
400-415 Vac
2 P+N+E
50 / 60 Hz
8.2 kW
14.2
20.0
---
E514B
400-415 Vac
2 P+N+E
50 / 60 Hz
6.8 kW
14.2
14.2
---
E516D
400-415 Vac
3 P+N+E
50 / 60 Hz
14.4 kW
20.0
20.0
20.0
E516C
400-415 Vac
3 P+N+E
50 / 60 Hz
13.2 kW
14.2
20.0
20.0
E516B
400-415 Vac
3 P+N+E
50 / 60 Hz
11.6 kW
14.2
14.2
20.0
E516A
400-415 Vac
3 P+N+E
50 / 60 Hz
10.2 kW
14.2
14.2
14.2
Summary of Contents for Blue Seal Evolution E512 Series
Page 7: ...5 E514 B E512 B E516 B Rating Plate Location for this option R R...
Page 8: ...6 E514 CB E516 CB Rating Plate Location for this option R R...
Page 9: ...7 E514 LS E516 LS Rating Plate Location for this option R R...
Page 21: ...1 E512 D E512 C...
Page 22: ...2 E514 D E514 C E514 B...
Page 23: ...3 E516 D E516 C...
Page 24: ...4 E516 B E516 A...
Page 26: ......