Programming the Control
Signal Terminals
01/02 AWB8230-1413GB
90
Setpoint value through keypad (OPE)
When you activate the digital input configured as OPE, an Enable
signal must be issued with the ON key on the keypad. If, for
example, you have entered the value 01 under PNU A001
(frequency setpoint input through analog input) and the value 01
under PNU A002 (start signal through digital input), these settings
become invalid as soon as you activate the OPE input. PNU A002
then contain the value 02 (start signal through ON key) and the
setpoint frequency under PNU A020 or PNU F001 becomes active.
If you activate the OPE input while the inverter is in RUN mode, it
decelerates and can then be started with the ON key on the device.
If the start signal is still active, the frequency inverter accelerates
to the previously set frequency again as soon as you deactivate the
OPE input.
X
Program one of the digital inputs 1 to 5 as OPE by entering the
value 31 under the corresponding PNU (C001 to C005).
Figure 82:
Digital input 1 configured as OPE
(setpoint definition through keypad)
OPE
FWD
P24
FW
1
Figure 83:
Function chart for OPE
(setpoint definition through keypad)
f
o
: Output frequency
PNU A020/
F001
OPE
FW
f
o
PNU
Name
Adjustable in RUN mode
Value
Function
WE
Normal
Extended
A001
Frequency
setpoint
definition
–
–
00
Definition with the potentiometer on the keypad
01
01
Definition through analog input O (0 to 10 V), O2 (
g
10 V) or
OI (4 to 20 mA)
02
Definition through PNU F001 and/or PNU A020
03
Definition through RS 485 serial interface
04
Setpoint definition through the optional module in slot 1
05
Setpoint definition through the optional module in slot 2
A002
Start signal
–
–
01
The motor start signal is issued through the FW input or a
digital input configured as REV.
01
02
The signal for starting the motor is issued by the ON key on
the keypad.
03
The motor start signal is issued through the RS 485
interface.
04
The motor start signal is issued through the optional module
in slot 1.
05
The motor start signal is issued through the optional module
in slot 2.
efesotomasyon.com - Klockner Moeller - inverter