GENERAL INFORMATION
MODY NON-CLOG VORTEX SS SLUDGE PUMPS have basically been designed and
manufactured with the highest quality components and used as heavy-duty
dewatering/wastewater units to pump out flooded installations or any other conditions that
need removal of solids laden unwanted fluids. The pumps are capable of handling water
contaminated with oil as well as stringy solids normally associated with raw and sewage
water with pH levels ranging from 3 - 10.
TECHNICAL DESCRIPTION
MOTOR
•
2Pole, 1 and 3 Phase continuous rated squirrel cage induction motor.
•
Stator insulation class H 180ºC, rated IP68
•
Speed: 3450RPM @60 Hz
•
Power rating: 0.5 to 10HP @ 60Hz
•
In-built Circle Thermal protection.
•
Max. Start/stop per hour 15
•
Service factor: 1.15
•
Max. fluid temperature 104F/40C
POWER SUPPLY
AC 1 phase, 60 Hz, 120V, 240V, and 3 phase, 240/480V
STARTING
METHOD
Plug-in, Float, DOL
OUTLET/
DISCHARGE
2”, 3”,4” NPT/Flange
PUMP ROTOR
SHAFT
Rugged aluminum die cast rotor dynamically balanced with a 410 duplex Stainless-
Steel shaft.
BEARINGS
Two single row deep groove Ball Bearings for Radial and thrust loads.
SEALS
Double SC/SC and Carbon/Ceramic mechanical seals enclosed in pressure
compensated oil chamber.
IMPELLER
Vortex 316SS
FRAME AND
OUTER CASE
316 stainless steel.
HARDWARE
316 Stainless steel
POWER CABLE
•
Waterproof/ oilproof, rubber-insulated, neoprene- sheathed cooper conductor
flexible cable.
•
UL SJTW/STOW, 50ft 4 core. (Optional Cable Lengths Available)
VOLUTE
•
316 Stainless Steel. Spherical solids handling 1.5” (38mm) & 2” (50mm).
SUBMERGENCE
MIN: 2”, MAX: 65’ (20m). (Below liquid surface)
ORINGS/
ELASTOMERS
FKM - VITON.
LIQUID DATA
Temp.: 104
°
F (40
°
C); pH Range 3 – 11; Specific Gravity: 1.1 Max
OPTIONAL
GUIDE RAIL SYSTEM
Summary of Contents for MSVSS
Page 10: ...TROUBLESHOOTING...
Page 11: ...SPECIFICATIONS AND DIMENSIONS MSVSS05 1...
Page 12: ...MSVSS1 1...
Page 13: ...MSVSS2 1...
Page 14: ...MSVSS2 3...
Page 15: ...MSVSS3 3...
Page 16: ...MSVSS3 5...
Page 17: ...MSVSS4 7 5...
Page 18: ...MSVSS4 10...
Page 19: ...TUS2 MSVSS0 5 1 TUS2 MSVSS1 1...
Page 20: ...TUS2 MSVSS2 1 TUS2 MSVSS2 3...
Page 21: ...TUS3 MSVSS3 3 TUS3 MSVSS3 5...
Page 22: ...TUS4 MSVSS4 7 5 TUS4 MSVSS4 10...
Page 23: ...TUS2 3 Upper Guide Rail Bracket TUS4 Upper Guide Rail Bracket...
Page 24: ...MSVSS0 5 1...
Page 26: ...MSVSS1 1...
Page 28: ...MSVSS2 1...
Page 30: ...MSVSS2 3...
Page 32: ...MSVSS3 3...
Page 34: ...MSVSS3 5...
Page 36: ...MSVSS4 7 5...
Page 38: ...MSVSS4 10...