10. TURN OIL BAG INSIDE OUT AND FIT OIL BAG "VEE" SECTION INTO GROOVE IN SEAL 
HOUSING(28).USING SMALL OIL BAG CLAMPS AND SCREWS &  NUTS CLAMP THE OIL BAG TO 
THE SEAL HOLDER. TURN OIL BAG TO CLAMP THE LARGER SIDE "VEE" SECTION TO THE 
GROOVE IN THE LOWER BEARING BRACKET IN THE SAME WAY. 
 
11. FIT ONE DRAIN PLUG WITH "O" RING IN LOWER BEARING BRACKET AND FILL OIL IN 
THE OIL BAG. PERIODICALLY PRESS THE OIL BAG TO LET AIR ESCAPE SO THAT FILLING  
IS PROPER AND NO AIR IS ENTRAPPED IN THE OIL BAG.(A SMALL AMOUNT OF AIR IN THE 
OIL BAG WILL NOT BE DETRIMENTAL IN ANY WAY).REPLACE PLUG WITH "O" RING. 
 
12. SLIDE ON WEAR PLATE AGAINST LOWER BEARING BRACKET AND TIGHTEN THE SAME. FIT 
KEY(25) ON THE SHAFT AND SLIDE ON IMPELLER. CLEARANCES BETWEEN IMPELLER AND 
WEAR PLATE CAN BE ADJUSTED BY MEANS OF THE TRIMMING SPACERS(27).TIGHTEN NUT(23) 
AND SEE THAT ROTOR SHAFT IS FREE. 
 
13. FIT OUTER CASING ON TOP BRACKET WITH "O" RING. FIT DIFFUSER AND ADJUST 
CLEARANCES. SLIDE ON DIFFUSER WASHERS(22) AND FIT DIFFUSER (19) AGAINST THE 
OUTER CASING(10). TIGHTEN BY MEANS OF NUTS(18). FIX STRAINER, BASE PLATE AND 
TIGHTEN NUTS(18) 
 

 
OIL SPECIFICATIONS

 

 
A) H.P. ENKLO OIL 46/48 
B) SHELL TELLUS 29. 
C) CHEVRON UNIVOLT 60/N61 
   
 

PARTS CATALOG

 

 
1. COMPONENTS LIST : AS PER DRAWING NO. DW/130/00 (SHEET 1 & 2). 

 

 
 
DRAWINGS :   

 
1. SECTIONAL ASSEMBLY(DW/130/00)(SHEET 1) 
 
2. SEALING ARRANGEMENT WITH MATERIAL PARTS LIST (DW/130/00)(SHEET 2)    
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for G 502 T

Page 1: ...TING INSTRUCTIONS INSTALLATION MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST Mody Pumps Inc 2166 Zeus Court Bakersfield CA 93308 Tel 661 392 7600 FAX 661 392 7601 EMAIL sales modypump com http www mod...

Page 2: ...e pump in its operating position so it does not tip over fall or slide 14 Keep away from impeller when power is connected 15 Submersible Pumps are not approved for use in swimming pools recreational w...

Page 3: ...SEAL FACES IRRESPECTIVE OF THE DEPTH SETTING OF THE PUMP OR THE HEAD AGAINST WHICH THE PUMP IS OPERATING IN mody SUBMERSIBLE SUMP PUMPS ALL WEAR PARTS ARE RUBBER LINED COVERED AND ARE READILY REPLACE...

Page 4: ...INKS AND SHARP BENDS 6 DO NOT LIFT OR PULL THE PUMP UNDER ANY CIRCUMSTANCES BY MEANS OF THE CABLE THE PUMP MUST BE LOWERED LIFTED FROM THE SPACE TO BE PUMPED BY USING A LIFTING ROPE ATTACHED TO THE HA...

Page 5: ...RD 1 SHIFT TWO PHASE CONN 2 PUMP WORN DOWN 2 REPLACE WEAR PARTS PUMP GIVES TOO LITTLE 3 LONG HOSE AND DIAMETER 3 CHECK PRESSURE LOSSES OUTPUT TOO SMALL 4 PRESSURE HEAD TOO HIGH 4 USE PUMPS IN TANDEM 5...

Page 6: ...DAM ARRANGEMENT IS PROVIDED WHICH SEALS THE INDIVIDUAL CORES OF THE CABLE THIS FEATURE IS UNIQUE AND IS ESSENTIAL TO PREVENT WATER SEEPING THROUGH THE CORES OF THE CABLE INTO THE CONTACTOR CHAMBER IN...

Page 7: ...SAND GUARD 69 FROM THE SEAL HOUSING 28 6 UNSCREW NUTS 18 AND FOUR STUDS 17 AND REMOVE WEAR PLATE 29 THIS CAN BE EASILY DONE BY INSERTING TWO SCREWDRIVERS BETWEEN WEAR PLATE AND LOWER BRACKET 15 AND P...

Page 8: ...ND ALSO DAMAGE THE BEARINGS AND FIT CIRCLIPS ON TOP AND BOTTOM GROOVES ON SHAFT IF THE BEARINGS ARE SHRINK FITTED ON THE SHAFT HEAT THE BEARINGS IN OIL TO A MAXIMUM TEMPERATURE OF 120 DEGREES CELSIUS...

Page 9: ...RING 12 SLIDE ON WEAR PLATE AGAINST LOWER BEARING BRACKET AND TIGHTEN THE SAME FIT KEY 25 ON THE SHAFT AND SLIDE ON IMPELLER CLEARANCES BETWEEN IMPELLER AND WEAR PLATE CAN BE ADJUSTED BY MEANS OF THE...

Page 10: ...2 SETS 4 CABLE GROMMET 260 013 66 2 NOS 5 CABLE LEAD GROMMET 260 014 66 2 NOS 6 UPPER BEARING 020 005 07 1 NO 7 LOWER BEARING 020 011 07 1 NO 8 STRAINER 640 012 11 1 NO 9 IMPELLER G 502T 60Hz 300 033...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ...rrected for field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccurac...

Reviews: