Lighting Fixture
1-20-6 BF1 Ebisuminami,Shibuya-ku,
Tokyo,150-0022,Japan
Tel : 81-3-5768-3681
5-6-9 Shinosakadaiichi9F Nishinakajima,
Yodogawa-ku,Osaka,532-0011,Japan
Tel : 81-6-6305-3501
1-8-30-1 Daimyou,Chuou-ku
Fukuoka,810-0041,Japan
Tel : 81-92-732-4211
TOKYO
OSAKA
FUKUOKA
To install ModuleX safety
MMP-130A/40BZ1/2
Installation Details
Installation Diagram
Caution
Locate fixture between joists.
Extend bar hangers to fit between
joists. Position fixture by hammering
nails into joists. Bar hangers should
be level with bottom of joists.
1
Installation in New Construction
2
Wiring connection
Installation Guide
R
MUSEUM platform / Adjusytable downlight
Installation Details
Installation Diagram
Caution
Cut out a hole and install the
mounting frame
Mounting frame
1
Install the mounting equipment
for ceiling cut out
Slide the metal fittings from upper
side
On step 2, please fix the metal
fitting firmly with your fingers.
If not, it may cause falling of fixtures
Metal fitting
Ceiling cut out
Use a screw driver and tighten the
metal fittings
1
2
2
3
a
a
b
b
3
Standard to screw
torque 1.0〜2.0N・m
Push tight
Φ130
Make sure to tighten the metal
fittings securely with a screwdriver.
(torque 1.0 〜2.0 N・m) If it is loose,
it may cause falling of the fixture
Ceiling
h
i
Ceiling Line
Bar hanger lip fits
against joist bottom
1
2
1
2
3
Remove the fixture wiring box
cover.
Remove appropriate round knock-
out(s) and connect conduit to
wiring box with proper connect-
or(s)(not included).
for metal conduit
Provide electrical service according
to the “National Electrical Code” or
your local electrical code from a
suitable junction box to the
wiring box(located on the plaster
frame).Supply wire insulation must
be rated for at least 75℃.
Make certain no bare wires are
exposed outside the connectors.
Connect supply wires to wires in
fixture wiring box with proper size
wire nuts(not included).Be sure
to cover all bare current carrying
conductors.Connect white to white;
black to black; and green or bare
copper wire(from electrical service)
to bare copper wire(in wiring box)
2
4
Place wires and connections back in
wiring box and replace cover.
Install with MINIMUM SPACINGS
between (a) center-to-center
of adjacent luminaires:
600 mm ( 24̲ in);
(b) top of luminaire to
overhead building member:
200 mm ( 8 in);
(c) luminaire center to side
building member:
300 mm ( 12 in)
(a)
(a)
(b)
(c)
DRIVER
*Wire nuts by others.
BLACK
WIRE NUT*
BLACK
WHITE
WHITE
WIRE NUT*
WIRE NUT*
GREEN OR BARE
GREEN OR BARE
3
PURPLE
GREY
CAPPED 0-10V
CONTROL WIRES
TO 0-10V DIMMER