background image

  

 

 
 
 

True Sinewave Power Inverter 

 
 
 

21060-03

 

 
 

 

Owner’s Manual 

 
 
 
 
 
 
 

.                                                                             

 

 
 
 
 
 

For safe and optimum performance, the Power Inverter must be used properly. Carefully read 
and follow all instructions and guidelines in this manual and give special attention to the 

CAUTION 

and 

WARNING 

statements. 

 
 
 

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE 

 

Disclaimer 

While every precaution has been taken to ensure the accuracy of the contents of this guide, 

Modul-System 

assumes no responsibility for errors or omissions. Note as well that 

specifications and product functionality may change without notice.

 

 

Important 

Please be sure to read and save the entire manual before using your 

Modul-System Power 

Inverter

. Misuse may result in damage to the unit and/or cause harm or serious injury. Read 

the manual in its entirety before using the unit and save the manual for future reference. 

 
 

True Sinewave Series: 
   

21060-03      12V 600W 230VAC True Sinewave Inverter 

(Schuko - CEE 7/4) 

 
 

P/N: MSIN600W Rev 1.1 
 
 
 
 
 
 
Service Contact Information 

Email: [email protected] 
Phone: 

+46 31 746 87 00 

 
Web: 

www.modul-system.com 

 

1.  INTRODUCTION 

Thank you for purchasing the Modul-System Power Inverter. With our state of the art, easy to 
use design, this product will offer you reliable service for providing AC power for your vehicle, 
trailer or container. The Modul-System Power Inverter can run many AC-powered appliances 
when you need AC power anywhere. 
This manual will explain how to use this unit safely and effectively. Please read and follow 
these instructions and precautions carefully. 
 

IMPORTANT SAFETY INFORMATION 

This section contains important safety information for the Modul-System Power Inverter. Each 
time, before using the Modul-System Power Inverter, READ ALL instructions and cautionary 
markings on or provided with the inverter, and all appropriate sections of this guide. 
The Modul-System Power Inverter contains no user-serviceable parts. See Warranty section 
for how to handle product issues. 
 

WARNING: Fire and/or chemical burn hazard 

• Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment. 

WARNING: Failure to follow these instructions can result in death or series injury 

•  When working with electrical equipment or lead acid batteries, have someone nearby in case 

of an emergency. 

•  Study and follow all the battery manufacturer’s specific precautions when installing, using 

and servicing the battery connected to the inverter. 

•  Wear eye protection and gloves. 
•  Avoid touching your eyes while using this unit. 
•  Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If 

this occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek 
medical attention. 

•  Batteries produce explosive gases. 

DO NOT 

smoke or have an open spark or fire near the 

system. 

•  Keep unit away from moist or damp areas. 
•  Avoid dropping any metal tool or object on the battery. Doing so could create a spark or 

short circuit which goes through the battery or another electrical tool that may create an 
explosion. 

WARNING: Shock Hazard. Keep away from children! 

•  Avoid moisture. Never expose unit to snow, water etc. 
•  Unit provides household AC, treat AC output sockets the same as regular wall AC sockets at 

home. 

WARNING: Explosion hazard!

 

•  DO NOT use the Modul-System Power Inverter in the vicinity of flammable fumes or gases 

(such as propane tanks or large engines). 

•  AVOID covering the ventilation openings. Always operate unit in an open area. 

 

EMC INFORMATION  

This equipment has been tested and found to comply with the limits for CE EMC standard. 
These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures:  
•  Re-orient or relocate the receiving antenna.  
•  Increase the separation between the equipment and the receiver.  
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.  

•  Consult the dealer or an experienced radio/TV technician for help. 

 
LIMITATIONS ON USE 

Do not use in connection with life support systems or other medical equipment or devices. 
 

2.  PRODUCT DESCRIPTION 

The Modul-System Power Inverter package includes the items list below. 
•  Power Inverter base unit 
•  Owner’s manual 
•  Cable boots 
•  Spare label 
 

3.  INSTALLATION 

WARNING: 

Modul-System recommends that all wiring be done by a certified technician or 

electrician to ensure adherence to the applicable electrical safety wiring regulations and 
installation codes. Failure to follow these instructions can damage the unit and could also 
result in personal injury or loss of life. 

CAUTION: 

Before beginning your power inverter Installation, please consider the following: 

•  The Power Inverter base unit should be used or stored in an indoor area away from direct 

sunlight, heat, moisture or conductive contaminants. 

•  When placing the unit, allow a minimum of 80 mm of space around the unit for optimal 

ventilation. 
 

 

Understanding the unit features  

 

 

Installation Preparation 

Typical wiring block diagram of the Power Inverter: 

 

Battery Bank: 

•  The use of deep cycle batteries is highly recommended for power inverter applications. 
•  For battery size, you need to identify how long you wish to operate the load(s). Modul-

System does recommend that you purchase as much battery capacity as 

possible, with a 

minimum of 60AH. See more on “Estimated Run time and Load” in Section 4.

 

•  Please use 12V Battery Bank system for the 21060-03 Power Inverter. Using 24V or 

higher voltage Battery Bank Systems will damage the inverter and may cause fire.  

Fuse or Circuit Breaker: 

•  DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required. 
•  Select a fuse or circuit breaker with 60A minimum rating. 
•  Based on the size of the battery bank chosen on the 12V system above, determine the 

overall short circuit current rating of the battery bank from the battery manufacturer. The 
fuse or circuit breaker chosen has to be able to withstand the short circuit current that may 
be generated by the battery bank. 

Disconnect Switch: 

•  Select a Disconnect Switch with the same or higher rating of the selected fuse or circuit 

breaker from the above. 

•  The Disconnect Switch is used to disconnect the DC power between the power inverter 

and the battery bank during service, maintenance or trouble shooting. 

 

Installing the Power Inverter System 

WARNING: Electrical Shock Hazard 

The unit green ‘

On/Off

’ switch does not disconnect the DC power from the battery. Use the DC 

Disconnect Switch or disconnect the DC input cables connection to disconnect the DC power 
from the battery before working on any circuits connected to the unit. Failure to follow these 
instructions can result in death or serious injury. 

CAUTION: Unit Damage 

Reversing the battery connection to the DC Input terminals will damage the unit and it cannot 
be repaired. Damage caused by reverse polarity connection is not covered by the warranty. 

 
Connect unit for Permanent use (cable not provided) 

•  Unit is for indoor use only, choose an appropriate mounting location. 
•  Orientation: Unit can be mounted in any direction. 
•  Use mounting template below to mark the positions of the mounting screws. Drill the 4 

mounting holes and place the inverter in position and fasten the inverter to the mounting 
surface. 

 

•  Use of low resistance cable is required for all the DC connections between the inverter and 

the battery bank. 

•  Use 

minimum 16mm

cable with maximum cable length of 3 meters for the Inverter system. 

•  Connect one end of the negative DC input cable to the Power Inverter DC negative (black) 

M5 terminal. 

•  Connect the other end of the negative DC input cable to the battery negative terminal or 

suitable chassis earth point. 

•  Make sure the Disconnect Switch is in the OFF position. 
•  Connect one end of the positive DC input cable to the Inverter DC positive (red) M5 

terminal. 

Reviews: