background image

75-506.10 

5H0703190000

INSTALLATION INSTRUCTIONS

vertical air deflector blades

gas, electric and oil-fired unit heaters

April, 2017

1.  Remove existing screws at the top and bottom of the air    

 

discharge opening. (For oil-fired models, screws are  

 

 

furnished in kit.)

2.  Place the mounting flanges (item #2) so that the    

 

 

indentations for the punched holes face each other, and    

 

attach with the screws removed in step 1.

3.  Insert the support rod (item #3) through the holes provided  

 

in the mounting flanges. Secure this support rod with the    

 

acorn push nuts (item #5) provided. 

4.  Assemble the coil spring (item #4) provided to the straight   

 

end of each deflector blade (item #1) and insert the ends of  

 

the blades with the coil springs into holes in mounting  

 

 

flanges. Push on the deflector blade until the beveded end   

 

slips into the holes of the opposite mounting flange.

5.  Adjust deflector blades to obtain desired direction of heat    

 throw.

For:

Gas Models PDP150 - PDP/BDP400

Electric Models HER30 - 250

Oil Models POR100 - POR185

*NOTE: DO NOT OPERATE UNIT WITH DEFLECTOR BLADES IN A CLOSED POSITION.

As Modine Manufacturing Company has a continuous products improvement program, it reserves the right to change design and 

specifications without notice.

page 1 of 2