Modern Forms Polar Series Installation Instructions Download Page 2

Modern Forms

www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585

Headquarters/Eastern Distribution Center

44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050

Western Distribution Center  

1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.   

AUG

 2019

2

INSTALLATION INSTRUCTIONS

 

Polar

WS-3218 / WS-3226

 / WS-3240

PREPARATION

1.  Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.

2.  Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

3.  Remove the knurling nut (C1).

4.  Remove the mounting screw (F1) and gasket (G1).

CONNECTING THE WIRES (Fig. 2)

5.  Connect the transformer’s input/output wires to the fixture wires as shown (Fig. 2). Make sure that all wire connectors (A1) are secure. 

If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground 

wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. 

NOTE:

 This fixture requires transformer to be recessed within the junction box.

MOUNTING THE FIXTURE

 

(Fig. 1)

6.  Secure mounting back plate to the junction box using junction box screws (B1).

NOTE: 

The side of the mounting back plate marked “GND” must face out

7.  Secure the mounting back plate to wall using the screws (I1) 

and the plastic anchors (J1).

8.  Place the fixture back plate over the mounting back plate 

and secure with knurling nut (C1). 

COMPLETING THE INSTALLATION (Fig. 1)

9.  Install the glass on the glass holder (H1) with 

mounting screws (D1) and gasket (E1).

10.  Secure the glass holder into the fixture back plate and 

secure with mounting screw (F1) and gasket (G1).

I1

J1

A1

B1

C1

E1

D1

F1

G1

H1

FIG.1

Fixture Wires

Black or 

Smooth

Fixture Wires

White or 

Ribbed

Fixture Wires

Bare wire

(Ground)

House Wires

Black

(Hot)

House Wires

White 

(Neutral)

House Wires

Green or Bare Copper

(Ground)

Fig.2  Wiring

Glass

Glass 

Holder

Mounting 

Screw

Mounting 

Screw

Knurled Nut

Diffuser

Connectors

Junction Box 

Screw

Plastic 

Washer

Gasket

Fixture Backplate

Mounting Screw

Mounting Backplate

Wire Connector

Junction Box

Ground Wire

Ground Wire

Screw

Transformer

Transformer  

Output Wires -Red

Mounting

Anchor

1

3

8"

1 3/4”

25 1/4”
20 1/2”

5 1/8”

Back Plate Dimensions