6. Making the Electrical Connections
WARNING
: Installation of this fan requires that a three-conductor
cable (including ground wire) which should run between ceiling and
wall outlet box.
WARNING
: Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire nuts,
except for the ground wire.
Insert the receiver into the mounting bracket with the flat side of the
receiver facing the ceiling (Fig. 6).
Motor to Receiver & Receiver to house supply wires (Fig. 6A).
1. Connect the hanger ball/downrod assembly ground wire,
mounting bracket ground wire and receiver ground wire to
the ground wire in outlet box.
WARNING
: Failure to connect ground wires could result in
poor fan control functionality.
2. Connect the red wire from the fan to the red wire marked
“
TO MOTOR
” from the receiver.
3. Connect the grey wire from the fan to the grey wire marked
“
TO MOTOR
” from the receiver.
4. Connect the yellow wire from the fan to the yellow wire marked
“
TO MOTOR
” from the receiver.
5. Connect the white wire from the fan to the white wire marked
“
FOR LIGHT
” from the receiver.
6. Connect the black wire from the fan to the black wire marked
“
FOR LIGHT
” from the receiver.
7. Connect the black (hot) wire from the ceiling to the black wire
marked “
AC in L
” from the receiver.
8. Connect the white (neutral) wire from the ceiling to the white
wire marked “
AC in N
” from the receiver.
Summary of Contents for FR-W1813
Page 1: ...Installation Instructions Morpheus works with the Google Assistant ...
Page 17: ...FR W1813 Morpheus Instructions 17 5A 5B ...
Page 23: ...FR W1813 Morpheus Instructions 23 8 ...
Page 25: ...FR W1813 Morpheus Instructions 25 9B 9 9A ...
Page 38: ...FR W1813 Morpheus Instructions 38 ...
Page 39: ...FR W1813 Morpheus Instructions 39 ...
Page 40: ...modernforms com FR W1813 ...