5. Making the Electrical Connections
Motor to Receiver & Receiver to house supply wires (Fig. 5A).
1. Connect the motor assembly ground wire, mounting bracket
ground wire and receiver ground wire to the ground wire in
outlet box.
WARNING
: Failure to connect ground wires could result in
poor fan control functionality.
2. Connect the red wire from the fan to the red wire marked
“
TO MOTOR
” from the receiver.
3. Connect the grey wire from the fan to the grey wire marked
“
TO MOTOR
” from the receiver.
4. Connect the yellow wire from the fan to the yellow wire marked
“
TO MOTOR
” from the receiver.
5. Connect the white wire from the fan to the white wire marked
“
FOR LIGHT
” from the receiver.
6. Connect the black wire from the fan to the blue wire marked
“
FOR LIGHT
” from the receiver.
7. Connect the black (hot) wire from the ceiling to the black wire
marked “
AC in L
” from the receiver.
8. Connect the white (neutral) wire from the ceiling to the white
wire marked “
AC in N
” from the receiver.