2
INSTALLATION INSTRUCTIONS
419-Outdoor Wall Sconce
WS-W41912/WS-W41918
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
F
ig
. 3 Wiring
F
ig
. 1
F
ig
. 2
F
ig
. 4
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
JAN 2019
JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1.
Shut off the power at the circuit breaker and remove existing
fixture, including the crossbar.
2.
Carefully unpack your new fixture and lay out all the parts on
a clear area. Be careful not to lose any small parts necessary
for installation.
MOUNTING THE FIXTURE (Fig. 1)
3.
4.
Remove the back plate screw (B) and back plate from the
fixture.
Secure the back plate to the junction box using
the
screws
provided
with the junction box.
NOTE:
T
he side of the back plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 3)
5. Connect the fixture’s wires to house wires as shown
(Fig.3)
. Make sure that all wire connectors (A) are secured. If
your
outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the
fixture’s ground
wire directly to the fixture. After wires are connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION
6.
Secure the fixture to the mounting back plate using the back plate screw (B) and rubber gasket (C).
7.
To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone
sealant) to outline the outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow
moisture to escape
(Fig.4)
.
Junction Box
Wire Connector
Junction Box Screw
Fixture
A
Back
P
late Screw
B
Rubber Gasket
C
Back
P
late
Junction Box
Caulking
2 3/8
"
1 3/8
"
4 5/8
"
4 1/2"
Back Plate Dimensions